Operating preset memory (PMEM)

The preset memory of a remote camera can be operated from the unit. The following settings that you have adjusted in advance can be stored in preset memory.

zzPan/tilt positions zzLens iris settings (manual iris only)

zzZoom positions zzWhite balance settings zzFocus positions

Notes

zzIf the MEM ENABLE button indicator is off, preset memory operation is not possible. Press the button to turn on its indicator and then perform operation.

zzPreset numbers PMEM 1 to 10 are also used as start positions when recalling tracing memory. Preset data may be overwritten or deleted by tracing memory operation.

zzThe number of preset memory and data that can be registered differ depending on the remote camera.

For details, check the operating instructions for the corresponding model.

MEM SETTING button

MEM ENABLE button

MEM DELETE button

PMEM button

MEM STORE button

PMEM PAGE

indicators

PMEM PAGE

button

Number buttons

[1] to [50]

zzChanging pages

Press one of the number buttons [1] to [50] to directly select any of the 50 preset memory.

Furthermore, pressing the PMEM PAGE button to change pages allows you to operate up to 100 preset memory for each camera.

Button indicator on

Button indicator on

Press the PMEM

PAGE button

Page 1 selected

 

Page 2 selected

<Preset numbers and registered pages>

 

 

Preset number

Page number

Number button

PMEM 1 to PMEM 50

Page 1

 

[1] to [50]

PMEM 51 to PMEM 100

Page 2

 

 

 

Example: When specifying preset number “PMEM 51”

1.Press the PMEM page button to select Page 2.

2.Press number button [1].

zzLighting of number button indicators

The lighting method of the number buttons differs depending on the remote camera or pan-tilt head that the unit is controlling.

<Lighting method of number button indicators>

Remote cameras and

Lighting method of number button

pan-tilt heads

indicators

AW-HE50, AW-HE60,

The indicators of the number buttons with

AW-HE120

preset memory registered turn on.

AW-HE100, AW-PH360,

The indicator of the number button that

AW-PH405, AW-PH650,

was last pressed turns on.

AW-PH400

However, when preset memory is deleted

 

in DELETE mode, all of the number

 

buttons turn off.