Setup menus (continued)

OPERATION (continued)

No./Item

 

Description of setting

 

 

115*1

For setting whether to restrict the operation of the

EJECT SW

EJECT button on the front panel.

0000

REC :

INH

Operation is inhibited while the unit is in the

 

 

recording mode.

 

0001

OFF :

 

The EJECT button can be operated in all operation

 

modes.

 

 

 

118*1

For selecting whether to enable or disable recording

SP MODE

on a tape which has been recorded using a format

other than DVCPRO HD-LP.

INH

0000

OFF :

 

 

Recording onto the cassette tape is enabled.

 

0001

ON :

 

Recording onto the cassette tape is disabled.

 

 

119*1

For selecting whether or not to perform simultaneous

CONFI REC

playback during normal recording (Other than the

frame-by-frame shooting).

 

 

0000

OFF :

 

The output for simultaneous playback during

 

normal recoding is switched in accordance with the

 

menu item No.140 OUTPUT.

 

EE:

EE output

 

TAPE:

Simultaneous playback output

 

0001

ON :

 

Simultaneous playback during normal recoding is

 

performed at all times, regardless of the setting of

 

the menu item No.140 OUTPUT.

 

 

134

For selecting the alarm sound for condensation,

ALARM

termination of the tape (remaining time of about 2

BEEP

minutes) or running out of battery power.

 

0000

OFF :

 

The alarm sound is not activated.

 

0001

ON :

 

The alarm sound is activated.

 

<Note>

 

 

If "ON" is selected in menu item No. 152 HUMID

 

OPE, the alarm sound for condensation is not

 

activated even if "ON" is selected.

 

 

140*1

For selecting the output signals.

OUTPUT

0000

EE :

<In the STOP mode>:

 

 

The input signals selected by the setting of the

 

INPUT SELECT button are output.

 

<During recording or editing>:

 

The input signals selected by the setting of the

 

INPUT SELECT button are output:

 

0001

TAPE :

 

<In the STOP mode>

 

The signals played back from the tape are output.

 

<During recording or editing>:

 

The simultaneous playback signals are output.

 

<Note>

 

 

In order to select the output signals during recording

 

or editing, set menu item No.119 CONFI REC or

 

No.302 CONFI EDIT.

 

 

 

No./Item

 

Description of setting

 

 

152

For setting the unit’s operation when condensation

HUMID OPE

has formed.

 

0000

OFF :

 

The unit does not operate when condensation has

 

formed.

 

 

0001

ON :

 

It operates even when condensation has formed

 

but no guarantees are made that the operation will

 

be trouble-free.

 

<Note>

 

 

Since operating the unit when condensation has

 

formed may damage the tape or give rise to other

 

trouble, the “OFF” setting is recommended under

 

normal circumstances.

 

 

154*1

For setting how the follow-on recording function is to

AUTO BACK

be used.

 

 

(For setting the AUTO BACK function operation which

 

rewinds the tape for several seconds in order to

 

ensure that the video images follow on one from

 

another with no disruptions.)

 

0000

OFF :

 

The tape is not rewound automatically (no AUTO

 

BACK).

 

 

0001

REC-P :

 

The tape is rewound (AUTO BACK) during REC

 

PAUSE, and it then stops in the recording standby

 

status. (When PAUSE is released, the tape runs

 

up, and recording starts.)

 

0002

ALL :

 

In addition to the function of the 0001 REC-P

 

setting, the tape is rewound (AUTO BACK) during

 

REC PLAY, the tape immediately runs up, and

 

recording starts.

 

 

 

*1 Displayed menus may vary depending on the settings in menu No. 25 SYSTEM FREQ. For details, refer to “Menus which are displayed” (page 32).

“_____” indicates the factory setting.