Setup menus (continued)
OPERATION (continued)
No./Item |
| Description of setting | |
|
| ||
115*1 | For setting whether to restrict the operation of the | ||
EJECT SW | EJECT button on the front panel. | ||
0000 | REC : | ||
INH | |||
Operation is inhibited while the unit is in the | |||
| |||
| recording mode. | ||
| 0001 | OFF : | |
| The EJECT button can be operated in all operation | ||
| modes. |
| |
|
| ||
118*1 | For selecting whether to enable or disable recording | ||
SP MODE | on a tape which has been recorded using a format | ||
other than DVCPRO | |||
INH | |||
0000 | OFF : | ||
| |||
| Recording onto the cassette tape is enabled. | ||
| 0001 | ON : | |
| Recording onto the cassette tape is disabled. | ||
|
| ||
119*1 | For selecting whether or not to perform simultaneous | ||
CONFI REC | playback during normal recording (Other than the | ||
| |||
| 0000 | OFF : | |
| The output for simultaneous playback during | ||
| normal recoding is switched in accordance with the | ||
| menu item No.140 OUTPUT. | ||
| EE: | EE output | |
| TAPE: | Simultaneous playback output | |
| 0001 | ON : | |
| Simultaneous playback during normal recoding is | ||
| performed at all times, regardless of the setting of | ||
| the menu item No.140 OUTPUT. | ||
|
| ||
134 | For selecting the alarm sound for condensation, | ||
ALARM | termination of the tape (remaining time of about 2 | ||
BEEP | minutes) or running out of battery power. | ||
| 0000 | OFF : | |
| The alarm sound is not activated. | ||
| 0001 | ON : | |
| The alarm sound is activated. | ||
| <Note> |
| |
| If "ON" is selected in menu item No. 152 HUMID | ||
| OPE, the alarm sound for condensation is not | ||
| activated even if "ON" is selected. | ||
|
| ||
140*1 | For selecting the output signals. | ||
OUTPUT | 0000 | EE : | |
<In the STOP mode>: | |||
| |||
| The input signals selected by the setting of the | ||
| INPUT SELECT button are output. | ||
| <During recording or editing>: | ||
| The input signals selected by the setting of the | ||
| INPUT SELECT button are output: | ||
| 0001 | TAPE : | |
| <In the STOP mode> | ||
| The signals played back from the tape are output. | ||
| <During recording or editing>: | ||
| The simultaneous playback signals are output. | ||
| <Note> |
| |
| In order to select the output signals during recording | ||
| or editing, set menu item No.119 CONFI REC or | ||
| No.302 CONFI EDIT. | ||
|
|
|
No./Item |
| Description of setting |
|
| |
152 | For setting the unit’s operation when condensation | |
HUMID OPE | has formed. | |
| 0000 | OFF : |
| The unit does not operate when condensation has | |
| formed. |
|
| 0001 | ON : |
| It operates even when condensation has formed | |
| but no guarantees are made that the operation will | |
| be | |
| <Note> |
|
| Since operating the unit when condensation has | |
| formed may damage the tape or give rise to other | |
| trouble, the “OFF” setting is recommended under | |
| normal circumstances. | |
|
| |
154*1 | For setting how the | |
AUTO BACK | be used. |
|
| (For setting the AUTO BACK function operation which | |
| rewinds the tape for several seconds in order to | |
| ensure that the video images follow on one from | |
| another with no disruptions.) | |
| 0000 | OFF : |
| The tape is not rewound automatically (no AUTO | |
| BACK). |
|
| 0001 | |
| The tape is rewound (AUTO BACK) during REC | |
| PAUSE, and it then stops in the recording standby | |
| status. (When PAUSE is released, the tape runs | |
| up, and recording starts.) | |
| 0002 | ALL : |
| In addition to the function of the 0001 | |
| setting, the tape is rewound (AUTO BACK) during | |
| REC PLAY, the tape immediately runs up, and | |
| recording starts. | |
|
|
|
*1 Displayed menus may vary depending on the settings in menu No. 25 SYSTEM FREQ. For details, refer to “Menus which are displayed” (page 32).
“_____” indicates the factory setting.
41