Error messages (continued)

Error messages (continued)

Monitor display

Description

Corrective action

VTR

operation

 

 

 

 

 

 

 

E-55

If the tape has not been taken up during unloading, this error

Set the POWER switch to OFF

STOP

UNLOAD ERROR

number flashes on the display.

and then to ON again.

 

 

 

 

 

E-57

If the start or end processing operation is not completed, this error

Set the POWER switch to OFF

 

S-FF/REW

STOP

TIMEOVER

number flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-59

If the cylinder motor speed is abnormally low, this error number

Set the POWER switch to OFF

 

DRUM ROTA TOO

STOP

SLOW

flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-60

If the cylinder motor speed is abnormally high, this error number

Set the POWER switch to OFF

 

DRUM ROTA TOO

STOP

FAST

flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-61

If the capstan motor speed is abnormally low, the error number

Set the POWER switch to OFF

 

CAP ROTA TOO

STOP

SLOW

flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-64

If the supply reel motor speed is abnormally high, the error number

Set the POWER switch to OFF

 

S REEL ROTA TOO

STOP

FAST

flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-67

If the take-up reel motor speed is abnormally high, the error number

Set the POWER switch to OFF

 

T REEL ROTA TOO

STOP

FAST

flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-69

If excess torque being applied to the take-up reel motor is detected,

Set the POWER switch to OFF

 

T REEL TORQUE

STOP

ERR

the error number flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-70

If excess torque being applied to the supply reel motor is detected or

Set the POWER switch to OFF

 

S REEL TORQUE

an abnormal current flowing to the current detection resistor is

STOP

ERR

detected, this error number flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

E-71

If abnormal tension at the supply side is detected in the capstan

Set the POWER switch to OFF

 

CAP TENSION

STOP

ERROR

mode, the error number flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-72

If abnormal tension at the supply side is detected in the reel mode,

Set the POWER switch to OFF

 

REEL TENSION

STOP

ERROR

the error number flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-73

If the take-up reel motor has rotated in the reverse direction, this

Set the POWER switch to OFF

 

REEL DIR

STOP

UNMATCH

error number flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-74

If excess torque being applied to the cylinder motor is detected, this

Set the POWER switch to OFF

 

DRUM TORQUE

STOP

ERROR

error number flashes on the display.

and then to ON again.

 

 

 

 

 

 

 

 

E-78

If a problem has been encountered in communication between the

Set the POWER switch to OFF

 

servo microcomputer and mechanism relay board, this error number

STOP

M-IF COMM ERROR

flashes on the display.

and then to ON again.

 

 

 

 

 

E-bA

This appears when the input DC voltage has dropped below the

Check the output voltage of the

 

equipment supplying DC

STOP

BATTERY

undercut voltage.

power.

 

 

 

 

 

 

 

 

<Note>

Consult your dealer if the error message display persists even after the unit has been restarted.

63