Setup menus (continued)
No./Item |
| Description of setting |
|
| |
400 | For setting the time to be taken before the unit is set | |
STILL TIMER | in the tape protection mode when it is left standing in | |
| the STOP or STILL status. | |
| (Units: S = seconds, min = minutes) | |
| 0000 | 0.5S |
| 0001 | 5S |
| 0002 | 10S |
| 0003 | 20S |
| 0004 | 30S |
| 0005 | 40S |
| 0006 | 50S |
| 0007 | 1min |
| 0008 | 2min |
| <Note> |
|
| When a DV, DVCAM or an unused tape is used, or a | |
| DVCPRO HD/DVCPRO50/DVCPRO tape is used in | |
| the EE mode, any setting above 2 (10S) will result in | |
| a setting time of 10 seconds. | |
|
| |
401 | For setting the operation to be performed in the tape | |
SRC | protection mode when the unit is left standing in the | |
PROTECT | STILL status (JOG/VAR/SHTL). | |
| 0000 | STEP : |
| STEP FWD | |
| 0001 | HALF : |
| STANDBY OFF (HALF LOADING) | |
| <Note> |
|
| When STEP FWD is selected, the unit is | |
| automatically transferred to the standby OFF (half | |
| loading) mode when the unit is left standing in the | |
| STOP mode for a total of 30 minutes (or 1 minute for | |
| DV or DVCAM tape). | |
|
| |
402 | For setting the cylinder operation in the standby OFF | |
DRUM | (half loading) mode. | |
STDBY | 0000 | OFF |
| The cylinder stops rotating. | |
| 0001 | ON |
| The cylinder continues to rotate. |
403For setting the operation to be performed in the tape
STOP protection mode when the unit is left standing in the
PROTECT STOP status. | |
0000 | STEP : |
STEP FWD | |
0001 | HALF : |
STANDBY OFF (HALF LOADING) | |
<Note> |
|
When STEP FWD is selected, the unit is | |
automatically transferred to the standby OFF (half | |
loading) mode when the unit is left standing in the | |
STOP mode for a total of 30 minutes (or 1 minute | |
for DV or DVCAM tape). |
“_____” indicates the factory setting.
No./Item |
|
| Description of setting |
| |
|
| ||||
500*1 | For setting whether to output the VITC signal at the | ||||
VITC BLANK | position which is set using menu items No.501 VITC | ||||
|
| ||||
| 0000 | BLANK : |
|
| |
| The VITC signal is not output. |
| |||
| 0001 |
| THRU : |
|
|
| The VITC signal is output. |
| |||
| <Note> |
|
|
|
|
| This setting takes effect only with the SD output | ||||
| (analog composite output and SD SDI output). | ||||
|
| ||||
501*1*2 | For setting the position where the VITC signal is to be | ||||
VITC | inserted. |
|
| <625 mode> |
|
| <525 mode> |
|
| ||
| 0000 |
| 10L | 0000 | 7L |
| : |
| : | : | : |
| 0006 |
| 16L | 0004 | 11L |
| : |
| : | : | : |
| 0010 |
| 20L | 0015 | 22L |
| <Notes> |
|
|
|
|
| z The same line as the one selected by menu item | ||||
| No.502 VITC | ||||
| cannot be selected. |
|
| ||
| z This setting takes effect only with the SD output | ||||
| (analog composite output and SD SDI output). | ||||
|
| ||||
502*1*2 | For setting the position where the VITC signal is to be | ||||
VITC | inserted. |
|
| <625 mode> |
|
| <525 mode> |
|
| ||
| 0000 |
| 10L | 0000 | 7L |
| : |
| : | : | : |
| 0008 |
| 18L | 0008 | 13L |
| : |
| : | : | : |
| 0010 |
| 20L | 0015 | 22L |
| <Notes> |
|
|
|
|
| z The same line as the one selected by menu item | ||||
| No.501 VITC | ||||
| cannot be selected. |
|
| ||
| z This setting takes effect only with the SD output | ||||
| (analog composite output and SD SDI output). | ||||
|
| ||||
503*1 | For setting the synchronization of the internal time | ||||
TCG MODE | code generator. |
|
| ||
| 0000 |
| SW : |
|
|
| When the TCG switch on the front panel is set to | ||||
| REGEN or PRESET, the selection is complied. | ||||
| 0001 |
| AUTO : |
|
|
| REGEN or PRE is automatically selected | ||||
| depending on the operation mode. |
| |||
| When editing (including a chained shot): | ||||
| REGEN is selected. |
|
| ||
| Other than the above: PRE is selected. | ||||
|
| ||||
504*1 | For setting the operation mode in which the internal | ||||
RUN MODE | time code generator runs. |
|
| ||
| 0000 |
| REC : |
|
|
| The generator runs only while recording is in | ||||
| progress. |
|
| ||
| 0001 |
| FREE : |
|
|
| The generator runs while the power is on | ||||
| regardless of the unit’s operation mode. | ||||
|
| ||||
505*1 | For setting the signal to be regenerated when the | ||||
TCG REGEN | TCG (time code generator) is in the regeneration | ||||
| mode. |
|
|
|
|
| 0000 | TC&UB : |
|
| |
| Both the time code and user bits are regenerated. | ||||
| 0001 |
| TC : |
|
|
| Only the time code is regenerated. |
| |||
| 0002 |
| UB : |
|
|
| Only the user bits is regenerated. |
| |||
|
|
|
|
|
|
*1 Displayed menus may vary depending on the settings in menu No. 25 SYSTEM FREQ. For details, refer to “Menus which are displayed” (page 32).
*2 Even if the RESET button is pressed while pressing the SEARCH button, the value may not return to the factory setting.
45