Error messages (continued)
Displaying the warning informationzA warning message appears when a warning has occurred. “NO WARNING” appears when a warning has not occurred.
zWhen more than one warning has occurred simultaneously, move the joystick up or down to check the description of each warning.
Warning messages
Priority | Monitor display | Description | Corrective action | VTR operation | ||
|
|
|
|
|
|
|
High |
| If condensation is detected, the error number flashes and |
|
| ||
| the unit transfers to eject mode. The drum rotates after |
|
| |||
|
|
|
|
|
| |
|
|
|
| the cassette is ejected to eliminate the condensation. |
|
|
|
|
|
| Once the unit is released from condensation status, the |
|
|
|
|
| error message display is cleared and the VTR is able to |
|
| |
|
|
| be used. | Leave the power on and wait. | EJECT | |
|
|
| (DEW) | |||
|
|
| z If condensation is detected in the eject mode, the drum |
|
| |
|
|
|
|
|
| |
|
|
|
| starts rotating as soon as it is detected. |
|
|
|
|
|
| z If condensation is detected when the cassette has |
|
|
|
|
|
| been inserted, the drum rotation is stopped, and after |
|
|
|
|
|
| the tape is ejected, the drum starts rotating. |
|
|
|
|
|
|
|
|
|
|
|
| (When “SLTC” is selected in menu No. 032 REC REF) |
|
| |
|
|
| Appear when a time code for a signal input into the HD | Check the time code | Operation | |
|
|
| (INVALID | SDI IN connector is not stepping at the standard rate in | ||
|
|
| information of the input signal. | continues. | ||
|
|
| EMBEDDED TC) | synchronizing the image frames to be recorded with the | ||
|
|
|
|
| ||
|
|
|
| time code. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| If the cable connection is in | Signal input |
|
|
|
| loop status, reconnect to 1 to | and output | |
|
|
| Display if the IEEE1394 digital interface connection status | 1. | through the | |
|
|
| (1394 INITIAL | |||
|
|
| is irregular | If not using the loop | IEEE1394 | |
|
|
| ERROR) | |||
|
|
|
| connection, turn the POWER | digital interface | |
|
|
|
|
| ||
|
|
|
|
| switch OFF > ON. | is stopped. |
|
|
| This appears when the signals supplied from the | Check that the 1394 input has | No recording o | |
|
|
| (UNKNOWN SIG) | IEEE1394 digital interface are not DVCPRO/DV format | been connected properly. | perations are |
|
|
| signals. | possible. | ||
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| This appears when the initialization process fails during | Check the input signal. | Operation | |
|
|
| (NOT 1X 100M SIG) | communication via the IEEE1394 digital interface. | continues.*1 | |
|
|
|
| |||
|
|
|
| This appears when the compressed video signals |
|
|
|
|
| supplied from the IEEE1394 digital interface are irregular | Check the 1394 input signals.It | Operation | |
|
|
| signals. | is possible that playback | ||
|
|
| (INVALID VIDEO | |||
|
|
| z This warning appears only during recording operations. | signals of an unrecorded tape | continues.*1 | |
|
|
| SIG) | |||
|
|
| In such cases, no signals are recorded on the tape, | are being input. |
| |
|
|
|
|
| ||
|
|
|
| and only erasure of existing signals is performed. |
|
|
|
|
|
|
|
|
|
|
|
| This appears when the audio signals supplied from the | Check the 1394 input signals.It |
| |
|
|
| IEEE1394 digital interface are irregular signals. | is possible that signals other | Operation | |
|
|
| (INVALID AUDIO | z This warning appears only during recording operations. | than 1x playback signals are | |
|
|
| continues.*2 | |||
|
|
| SIG) | In such cases, the signals are recorded with the audio | being input from a VTR or | |
|
|
|
| signals muted. | other device. |
|
|
|
|
|
|
|
|
|
|
|
| This appears when the time code information supplied |
|
|
|
|
| from the IEEE1394 digital interface is irregular | Check the time code of the | Operation | |
|
|
| information. | |||
|
|
| device which is supplying the | |||
|
|
| (INVALID TC SIG) | z This warning appears only during recording operations. | continues.*3 | |
|
|
|
| In such cases, the internally generated time code is | time code. |
|
|
|
|
|
|
| |
|
|
|
| recorded. |
|
|
|
|
|
|
|
|
|
|
|
| This appears when the signals supplied to the IEEE1394 |
| Operation | |
|
|
| digital interface are at variance from the system format | Check the input signal. | ||
|
|
| (NO MATCH SIG) | continues.*1 | ||
|
|
| which is set by this unit. |
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| This appears when the fan motor has shut down. | Check the fan for foreign | Operation | |
|
|
| z The power automatically turns off if 5 minutes pass with | |||
|
|
| (FAN STOP) | matter. | continues. | |
|
|
|
| the fan stopped. |
|
|
|
|
|
| This appears when a blank section lasting for more than |
|
|
|
|
|
| one second on the tape has been detected during |
|
|
|
|
| playback. | Check the tape. It is possible |
| |
|
|
| A blank section is identified as such when all the following | Operation | ||
|
|
| (NO RF) | conditions are met: | that an unrecorded tape has | continues. |
|
|
| been loaded. | |||
|
|
|
| z There are no output signals from any of the heads. |
| |
|
|
|
|
|
| |
|
|
|
| z The playback data cannot be read. |
|
|
|
|
|
| z There is no CTL signal (DV/DVCAM tapes excluded). |
|
|
|
|
|
|
|
|
|
*1 This error message always appears in the EE mode.
In such a case, black signals are recorded as the video signals, and the audio signals are muted. *2: This error message always appears in the EE mode.
In such a case, the audio signals are muted.
*3: This error message always appears in the EE mode.
In such a case, the time code of the time code generator inside this unit is recorded as the time code signal.
61