Operation Basic

Remote control operation

Loading a saved setting

Displays the [MEMORY LOAD] menu.

Press

Attention

zzSetting can also be performed using the on-screen menu. For details, see [MEMORY LOAD] in the [PICTURE] menu. ( page 54)

Displaying the [VIERA LINK] menu

You can control some functions of the external device with this projector remote control.

Press

Note

zzSee “Using VIERA Link” for details. ( page 82)

Displaying the waveform monitor

By displaying the input signal from a connected external device with a waveform, you can check if the video signal (luminance) level is set to a value within this projector’s recommended range, and can adjust it accordingly.

Press

The settings change as follows each time the <ENTER> button is pressed.

[FULL

Checks that the waveform for each of the

Y‑ (brightness), R‑ (red), G‑ (green), and

SCAN]

B‑ (blue) values for the whole image is

 

within the recommended range.

 

Checks that the waveform for each of the

 

Y‑ (brightness), R‑ (red), G‑ (green), and

 

B‑ (blue) values for an arbitrary number

 

of lines from the top of the screen to the

[SINGLE

bottom is within the recommended range.

LINE

zzEnables more detailed confirmation than

SCAN]

[FULL SCAN].

zzLine position can be changed with the ▲▼

 

 

buttons.

 

zzThe display position of the [WAVEFORM

 

MONITOR] changes depending on the line

 

position.

Note

zzSignals lower than 0 % in the waveform monitor will be displayed as same as 0 % on the projected image.

zz[SINGLE LINE SCAN] can display horizontal lines in Y‑ (brightness), R‑ (red), G‑ (green), and B‑ (blue) from the top of the screen to the bottom more finely than [FULL SCAN], and each item can be adjusted in the same way as [FULL SCAN].

zzWhen selecting [FULL SCAN], the display position of the waveform can be set using the ▲▼▲▼ buttons.

zzSo that the display of individual adjustment screen in [PICTURE] does not interfere with the waveform monitor, the positioning of this screen differs depending on the circumstances at the time.

zzThe [AUTO ADJUST] is executed by pressing the <DEFAULT> button while the waveform is displayed. ( page 39)

zzWhile the waveform monitor is displayed, you cannot adjust the [COLOR MANAGEMENT] settings.

Resetting to the default settings

[FULL SCAN (Y)]

[SINGLE LINE SCAN (B)]

[SINGLE LINE SCAN (G)]

[SINGLE LINE SCAN (R)]

[FULL SCAN (R)]

[FULL SCAN (G)]

[FULL SCAN (B)]

[SINGLE LINE SCAN (Y)]

You can reset most of the settings or adjustment values for submenus to factory default settings.

Press

For details, see “Navigating through the menu - Returning adjusted values to default settings” of “Menu navigation”. ( page 34)

The waveform monitor disappears when the <WAVEFORM MONITOR> button is pressed again.

Note

zzSetting can also be performed using the on-screen menu. For details, see [WAVEFORM MONITOR] in [PICTURE] menu. ( page 39)

32 - ENGLISH