![](/images/backgrounds/153380/153380-9467x1.png)
[ECO MANAGEMENT]
You can reduce power consumption by optimizing the lamp power in accordance with the usage state.
Press the <ENTER> button.
zzThe [ECO MANAGEMENT] menu is displayed.
|
| PICTURE |
| ECO MANAGEMENT |
|
|
|
| AUTO POWER SAVE | ON | |
|
|
|
|
|
|
|
| POSITION |
| AMBIENT LIGHT DETECTION | ON |
|
|
| SIGNAL DETECTION | ON | |
|
|
|
| BLANK DETECTION | ON |
|
| LANGUAGE |
| SLEEP | OFF |
|
| OPTION |
|
|
|
Note
zz[LAMP POWER] may not automatically decrease in the following cases.
•• When [LAMP POWER] is set to [ECO].
•• Immediately after the lamp illuminates or after [LAMP POWER] is set.
zzWhen [AUTO POWER SAVE] is [OFF], [AMBIENT LIGHT DETECTION], [SIGNAL DETECTION], and [BLANK DETECTION] cannot be set.
■■[AUTO POWER SAVE]
Sets whether the functions [AMBIENT LIGHT DETECTION], [SIGNAL DETECTION], and [BLANK DETECTION] are active.
Switch settings | Switch settings |
[ON] Energy saving settings active
[OFF] Energy saving settings inactive
Note
zzSettings cannot be made when [LAMP POWER] is set to [ECO].
[OPTION] menu
■■[AMBIENT LIGHT DETECTION]
You can adjust the lamp power in accordance with brightness of the installation location.
Switch settings Switch settings
[ON] Adjust lamp power
[OFF] Do not adjust lamp power
■■[SIGNAL DETECTION]
You can reduce the lamp power when no signal is input.
Switch settings Switch settings
[ON] Adjust lamp power
[OFF] Do not adjust lamp power
■■[BLANK DETECTION]
You can reduce the lamp power when the signal is blank.
Switch settings Switch settings
[ON] Adjust lamp power
[OFF] Do not adjust lamp power
Settings
ENGLISH - 67