TEMP and LAMP Indicators

■Lamp indicator <LAMP>

Indicator

Illuminated red

Flashing red

status

 

 

 

 

 

 

 

 

Time to replace the lamp unit. Illuminates when

 

 

Problem

the lamp unit has reached its maximum usage

Lamp circuit failure, abnormal function or lamp unit

period of 1 800 hours (when [LAMP POWER]

is damaged.

 

 

 

 

is set to [NORMAL]).

 

 

 

 

 

 

 

 

The power may

Lamp circuit failure,

Cause

A message suggesting lamp replacement

have been turned on

abnormal function or

is displayed when power is turned on.

immediately after being

 

 

turned off.

lamp unit is damaged.

 

 

 

 

 

 

 

 

 

 

Press the <OFF> side

 

 

 

of the <MAIN POWER>

 

 

Let the lamp unit cool

switch to turn off the

Solution

 

power as described

Replace the lamp unit. ( page 77)

down and turn on the

in the “Switching off

 

 

power.

 

 

the power” procedure

 

 

 

 

 

 

( page 29), and

 

 

 

contact your dealer.

 

 

 

 

Note

zzIf the <LAMP> indicator is illuminated or flashes despite taking the actions above, please contact an Authorized Service Center to have your projector repaired.