Indication of monitor lamp

Three monitor lamps are provided at the top of main unit front to inform the user of the lamp replacement time and unusual internal temperature. These lamps indicate the degree of abnormality by combination of blinking and/or lighting lamps. Turn off the power and take the proper measure according to the table below.

TEMP LAMP1 LAMP2 POWER

 

 

 

 

 

 

 

 

 

 

 

 

Lamp 2 monitor (LAMP2)

 

 

 

 

 

 

 

 

 

 

 

 

Lamp 1 monitor (LAMP1)

 

 

 

 

 

 

 

 

 

 

 

 

Temperature monitor (TEMP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Name of monitor

 

 

Lamp

 

 

Information

 

 

 

Checkpoint

 

 

Remedial measure

 

 

lamp

 

 

indication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Did you turn on the

 

 

• Wait about five minutes in the

 

 

 

 

 

 

 

 

 

 

 

power when the

 

 

current status.

 

 

 

 

 

 

 

 

Warm-up status

 

 

ambient temperature

 

 

• Install the unit in a location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lighting in

 

 

 

 

 

was low (approx. 0

 

 

having an ambient

 

 

 

 

 

red

 

 

 

 

 

°C)?

 

 

temperature from 0 to 40 °C.

 

 

 

 

 

(lamp unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Remove the object that is

 

 

 

 

 

ON)

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

High temperature

 

 

• Check if the

 

 

blocking the ventilation port.

 

 

 

 

 

 

 

 

 

 

 

 

 

monitor

 

 

 

 

 

 

 

 

 

• Move the projector to a

 

 

 

 

 

 

 

inside. (WARNING)

 

 

ventilation port is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature of 0 to 40 ˚C and

 

 

 

 

 

 

 

 

 

 

 

blocked.

 

 

 

 

TEMP

 

 

 

 

 

 

 

 

 

 

the humidity of 20 to 80% (no

 

 

 

 

 

 

 

 

 

 

• Is the room air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

condensation).

 

 

 

 

 

 

 

 

 

 

 

temperature too high?

 

 

 

 

 

 

 

Blinking in

 

 

High temperature

 

 

 

 

• Turn off the MAIN POWER

 

 

 

 

 

red

 

 

inside

 

 

• Check the air filter for

 

 

switch using the procedure on

 

 

 

 

 

 

 

 

 

clogging.

 

 

 

 

 

 

 

(2 times)

 

 

(Standby condition)

 

 

 

 

page 40 and clean the air filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(refer to page 99).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking in

 

 

 

 

 

 

 

 

 

 

• Turn off the main power supply

 

 

 

 

 

 

 

Cooling fan has

 

 

 

 

 

 

 

(MAIN POWER) switch in the

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

been stopped.

 

 

 

 

 

 

 

procedure shown on page 40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3 times)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and consult the distributor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Did you notice a

 

 

• This lamp monitor lights up

 

 

 

 

 

 

 

 

 

 

 

“REPLACE THE

 

 

when the lamp unit used hours

 

 

 

 

 

Lighting in

 

 

Indicates the time

 

 

LAMP” message on

 

 

have reached 1 300 hours

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for replacing the

 

 

the screen when

 

 

(3 800 hours when Long Life

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

lamp unit.

 

 

turning on the

 

 

Lamp Units are used).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

projector power

 

 

Request the dealer to replace

 

 

Lamp monitor

 

 

 

 

 

 

 

 

supply.

 

 

the lamp unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Did you turn the

 

 

• Wait until the lamp has cooled

 

 

LAMP1 LAMP2

 

 

 

 

 

 

 

 

power back on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off, and then turn on the

 

 

 

 

 

 

 

 

 

 

 

immediately after

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power.

 

 

 

 

 

 

 

 

 

 

 

turning it off?

 

 

 

 

 

 

 

Blinking in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error is detected in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Some error has

 

 

 

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the lamp circuit.

 

 

arisen in the lamp

 

 

• Turn off the MAIN POWER

 

 

 

 

 

(3 times)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit.

 

 

switch using the procedure on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check for fluctuation

 

 

page 40 and consult the

 

 

 

 

 

 

 

 

 

 

 

(or drop) in the source

 

 

dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attention • Be sure to observe the procedure (How to turn “ON” and “OFF” the power supply) on page 39–40 when performing power supply operation to take a measure to the indication of temperature monitor (TEMP) lamp and lamp monitor (LAMP) lamp.

98

Page 98
Image 98
Panasonic PT-D7700U manual Indication of monitor lamp, Lamp Information Checkpoint Remedial measure, Monitor, Lamp monitor