14)If [CLOCK PHASE] is selected in Step 8), press qw to make adjustment.

15)Press as to select [FRAME LOCK].

16)Press qw to switch the item.

[MAIN WINDOW]

Set frame lock to the input signal set in the main window.

[SUB WINDOW]

Set frame lock to the input signal set in the sub window.

17)Press as to select [TYPE].

18)Press qw to switch the item.

[MAIN WINDOW]

The main window has display priority.

[SUB WINDOW]

The sub window has display priority.

Note

ff The P IN P function may not be available for some signals being input or terminals being selected. Refer to “Two-window display combination list” (x page 146) for details.

ff The main window setting values are applied to image adjustment values such as [PICTURE MODE], [GAMMA], and [COLOR TEMPERATURE].

ff On the normal screen (when no menu is displayed), press as to switch the size and position of the main window and sub window while P IN P is operating.

ff If the signals from the <RGB 1 IN> or <RGB 2 IN> terminal are input to either the main window or the sub window, and those input signals are analog RGB or YCBCR/YPBPR signals, the signals are output from the <MONITOR OUT> terminal. If input combination of the main window and sub window is RGB1 and RGB2, the signals of the main window take priority for output.