Chapter
6)Press qw to switch the item.
ff The items will switch each time you press the button.
[9600] |
|
[19200] | Select the proper speed. |
[38400] |
|
7)Press as to select [PARITY].
8)Press qw to switch the item.
ff The items will switch each time you press the button.
[NONE] |
|
[EVEN] | Select the parity condition. |
[ODD] |
|
When controlling the projector on a computer, set use of control commands on a previously purchased Panasonic projector. This allows the
control software for an existing Panasonic projector to be inherited and used.
1)Press as to select
2)Press the <ENTER> button.
ff The
3)Press as to select [EMULATE].
4)Press the <ENTER> button.
5)Press as to select an item.
[DEFAULT] | EZ770 series, EW730 series, EX800 series, RZ475 series, RZ470 series, RW430 series, RZ370 | |
series, RW330 series | ||
| ||
[D3500] | D3500 series | |
[D4000] | D4000 series | |
[D/W5k SERIES] | D5700 series, DW5100 series, D5600 series, DW5000 series, D5500 series | |
[D/W/Z6k SERIES] | DZ770 series, DW740 series, DX810 series, DZ680 series, DW640 series, DX610 series, DW730 | |
series, DX800 series, DZ6710 series, DZ6700 series, DW6300 series, D6000 series, D5000 series, | ||
| DZ570 series, DW530 series, DX500 series | |
[L730 SERIES] | L730 series, L720 series, L520 series | |
[L780 SERIES] | L780 series, L750 series | |
[L735 SERIES] | L735 series | |
[L785 SERIES] | L785 series | |
[F/W SERIES] | FW430 series, FX400 series, FW300 series, F300 series, F200 series, FW100 series, F100 series | |
[LZ370] | LZ370 series | |
[LB/W SERIES] | LB3 series, LB2 series, LB1 series, ST10 series, LB90 series, LW80NT series, LB80 series, LB78 | |
series, LB75 series | ||
| ||
[VX500 SERIES] | VW435N series, VW440 series, VW430 series, VX505N series, VX510 series, VX501U, VX405KEA, | |
VX45KEA, VX500 series, VW330 series, VX400NT series, VX400 series, VX41 series | ||
| ||
[EZ570 SERIES] | EZ570 series, EW630 series, EW530 series, EX600 series, EX500 series | |
[VW431D] | VW431D series |
6)Press the <ENTER> button.
7)When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.
Note
ff When [INPUT SELECT] is set to [DIGITAL INTERFACE BOX], communication using that serial terminal is available only when the corresponding device (such as the optional Digital Interface Box (Model No.: ET‑YFB100G)) is connected to the <DIGITAL LINK/LAN> terminal.
ff When transferring logos via the optional Digital Interface Box (Model No.: ET‑YFB100G), “NO SIGNAL SLEEP” of ET‑YFB100G must be set to “OFF” to avoid cutting off communication.
ff When [INPUT SELECT] is set to [DIGITAL INTERFACE BOX], communication speed is fixed to 9 600 bps.
ENGLISH - 93