5 –MOUNT THE DRIVE

Dimensions of the E-AC Drive are shown below.

4.34

(110.1)

4.10

(104.1)

0.43

(10.8)

5.35

(135.9)

4.500

(114.3)

Dimensions in inches (mm)

2x clearance for

 

#8 or M4 mounting screws

Dimensions – E-AC Drive

1.89

(48.1)

0.18

(4.6)

1.59

(40.5)

 

I/O

SERIES

DRIVE

PWR/FLT

L1

120V

N

 

 

A +

MOTOR

A -

 

 

B +

 

 

B -

 

 

Compumotor

ENVIRONMENTAL CONSIDERATIONS

TEMPERATURE SPECIFICATIONS

 

 

Maximum Ambient Temperature:

50° C

(122° F)

Minimum Ambient Temperature:

0° C

(32° F)

Overtemperature Shutdown Fault:

55° C

(131° F)

The E-AC Drive has an internal temperature sensor, located near the heatsink. If the sensor reaches 55° C (131° F), it will trigger an overtem- perature fault, and the drive will shut down.

FAN COOLING

Operating the E-AC Drive in high ambient temperatures may require fan cooling to keep the drive from shutting down due to an overtemperature fault.

HUMIDITY

Keep the relative humidity below 95%, non-condensing.

LIQUIDS

Do not allow liquids or fluids to come into contact with the E-AC Drive or its cables.

AIRBORNE CONTAMINANTS

Particulate contaminants, especially electrically conductive material such

E-AC Drive Hardware Installation Guide