Regulatory Agencies
The
The
Agency | Additional Steps User Must Take |
UL, cUL | No additional steps are required. (The |
| shipped from the factory.) |
CE (LVD) | Earth connection for drive and motor (if applicable), proper installation |
CE (EMC) | Varistors, mains filter, EMC cabling, EMC ready motor, proper installation |
Installation Instructions
Although the
The following constitutes what is typically required to install the
Low Voltage Directive (LVD) Installation Requirements:
•Drive safety earth conductor
•Motor safety earth
•Drive must be installed such that the hazardous live terminals (barrier strip) are not accessible under normal operation
Electromagnetic Compatibility (EMC) Installation Requirements:
•Product does not need to be placed within an enclosure
•Mains filter (see filter recommendations)
•Transient suppressors (mains surge test)
•EMC cabling, braided and bonded as specified below
•EMC ready motor, or motor with EMC installation information
•Additional installation hardware as shown in drawings in this appendix
Additional Steps to Ensure Compliance
To meet the requirements of regulatory agencies, you must follow the installation guidelines presented below.
EMC –Electromagnetic Compatibility Directive –89/336/EEC
In order to meet the requirements of the Electromagnetic Compatibility Directive 89/336/EEC, the entire system must comply: motor, drive, cabling, and peripher- als. The installation of the product must include the following items.