Patton electronic 3088 Configuration Reset to Factory Defaults, Dip Switch Settings, Position

Models: 3088

1 48
Download 48 pages 47.56 Kb
Page 13
Image 13

Configuration Reset to Factory Defaults

To recover from a forgotten password, the user may reset the unit to its factory configuration. After seeing the “Reset Mode” message, the user should type the ‘*’ key. This will result in a ‘:’ prompt. At the prompt, the user should enter the command reset. This will restore the unit to the fac- tory configuration. The unit can then be restarted with the settings

in place.

4.3 DIP SWITCH SETTINGS

The 3088 can be configured with DIP switches. If the DIP switches are set to anything other than all ON, then the unit will be in DIP switch con- figuration. In DIP switch configuration, the console and EOC cannot be used to change configuration.

The following table describes the DIP switch functions.

Position

Function

Factory Default

 

 

 

 

S1-8

TX Clock

ON

Normal

S1-7

Data Rate

ON

256K

 

 

 

 

S1-6

 

ON

 

 

 

 

 

S1-5

 

ON

 

 

 

 

 

S1-4

 

ON

 

 

 

 

 

S1-3

 

ON

 

 

 

 

 

S1-2

 

OFF

 

 

 

 

 

S1-1

 

OFF

 

 

 

 

 

S2-8

Reserved

OFF

 

 

 

 

 

S2-7

 

OFF

 

 

 

 

 

S2-6

DTE Loops

OFF

Disabled

 

 

 

 

S2-5

Clock Mode

OFF

Receive-

 

 

 

Recover

S2-4

 

ON

 

 

 

 

S2-3

Annex

OFF

Annex B

 

 

 

 

S2-2

Line Probe

ON

Disabled

 

 

 

 

S2-1

Front Panel Switches

OFF

Enabled

 

 

 

 

13

Page 13
Image 13