Patton electronic user manual 3096RC CO, 3088 CP

Models: 3088

1 48
Download 48 pages 47.56 Kb
Page 27
Image 27
3096RC

Follow the instructions below to activate RocketLink Plug ‘n’ Play between CO (Model 3096RC and CP (Model 3088) units:

Set the Model 3096RC (CO) to either Internal or External clocking mode as defined by the application.

Set the Model 3088 (CP) to “RocketLink Plug-and-Play CP” by setting S1 and S2 DIP switches in the ON position as described in figure 4.

3096RC

(CO)

DSL Span

3088

(CP)

DIP Switches or NMS configured

DIP Switches all in ON position

according to specific application

 

requirements

 

Figure 4. Typical RocketLink Plug ‘n’ Play Application

When the CO and CP units connect over DSL, the CP will enter a pre- defined default configuration (Receive Recovered Clocking). During the negotiation process between the units, the CO unit will configure the DTE rate/line rate on the CP unit as defined by the settings of the CO unit. When additional bandwidth is required, only the configuration of the CO unit should be changed. This feature gives ISPs, LECs and PTTs the ability to provision bandwidth on an as needed basis to customers.