Patton electronic Term Green, 3088/D with the X.21 interface, TM/ER Red, Test Modes, Loopbacks

Models: 3088

1 48
Download 48 pages 47.56 Kb
Page 34
Image 34
Term (Green)

Term (Green)

The Term LED glows solid under the following circumstances:

3088/CA with V.35 interface: If the serial interface has asserted DTR

3088/D with the X.21 interface:

Configured as DCE : Indicates that the “Control” signals have been asserted.

Configured as DTE : Indicates that the “Indication” signals have been asserted

TM/ER (Red)

The TM/ER LED is used to indicate that a test mode is in progress or an error has been detected. It blinks once every second while a test mode is starting. It glows solid while a test mode is in progress. It blinks once if an error is detected either during a test mode, or in normal DSL operation.

6.3 TEST MODES

The 3088 offers test modes in the form of loopbacks, PRBS pattern gen- erators, and combinations of both. This section discusses how the test modes work. Figure 12 is a block digram of the Model 3088 with respect to test modes.

511Pattern Generator

511BER

Meter

DSL

Framer

Line

DSL

Framer

511Pattern Generator

511BER

Meter

Figure 12. Model 3088 Block Diagram

Loopbacks

The 3088 supports both Local Analog Loopbacks (LAL) and Remote Digital Loopbacks (RDL). These can be initiated either from the optional front panel switches or by the console command dsl set loopback <offlalrdl>. The data path for the LAL is shown in figure 13.