Patton electronic 3088 Patterns, Local Analog Loopback diagram, Remote Digital Loopback diagram

Models: 3088

1 48
Download 48 pages 47.56 Kb
Page 35
Image 35
Figure 13. Local Analog Loopback diagram

.

511Pattern Generator

511BER

Meter

DSL

Framer

Line

DSL

Framer

511Pattern Generator

511BER

Meter

Figure 13. Local Analog Loopback diagram

The data received from the serial interface is looped back before going out on the DSL line. Note that this loopback occurs after the pattern gen- erator/BER meter. This means that running a 511 pattern is conjunction with an LAL should result in no error detected by the meter.

The data path for the RDL is shown in figure 14.

511 Pattern

 

Line

Generator

 

511 BER

DSL

DSL

Meter

 

Framer

Framer

511Pattern Generator

511BER

Meter

Figure 14. Remote Digital Loopback diagram

The RDL causes the remote unit to loop the data received from the DSL line back to the DSL line.

Patterns

The 3088 can generate and detect 511 and 511 with Error patterns. These can be initiated either by the optional front panel switches or by the console command dsl set pattern <off511511e>. When the pattern is started, the DSL framer uses its internal 511 pattern generator for its DSL TX data instead of the data received from the serial interface. Also, the framer’s internal BER Meter tries to detect a 511 pattern in the DSL RX Data.

Because the BER Meter always runs when the pattern generator runs, the meter will detect errors if either the pattern is not either looped back or the remote unit is not transmitting a 511 pattern.

One point to note is that the way errors are generated in the 511E pat- tern generates CRC errors. This can cause the DSL error monitor to restart the link if the thresholds are set low enough.

35

Page 35
Image 35
Patton electronic 3088 user manual Patterns, Local Analog Loopback diagram, Remote Digital Loopback diagram