Patton electronic 3088 Loops, S2-6, S2-5 - S2-4 Clock Mode, S1-7, S1-6, S1-5, S1-4, S1-3, S1-2

Models: 3088

1 48
Download 48 pages 47.56 Kb
Page 16
Image 16

S1-7

S1-6

S1-5

S1-4

S1-3

S1-2

S1-1

Data Rate

(kbps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

ON

ON

ON

OFF

ON

ON

4352

OFF

ON

ON

ON

OFF

ON

OFF

4416

 

 

 

 

 

 

 

 

OFF

ON

ON

ON

OFF

OFF

ON

4480

 

 

 

 

 

 

 

 

OFF

ON

ON

ON

OFF

OFF

OFF

4544

 

 

 

 

 

 

 

 

OFF

ON

ON

OFF

ON

ON

ON

4608

 

 

 

 

 

 

 

 

Loops

The V.35 interface has pins two pins, one to request an LAL and the other to request and RDL. If DTE loops are enabled, then when these pins are asserted, the 3088/C will start a local loopback or a remote loopback. If DTE loops are disabled, these requests will be ignored.

S2-6

Setting

 

 

ON

Enabled

OFF

Disabled

 

 

S2-5S2-4: Clock Mode

The 3088 has three clock modes: internal, external, and receive-recover.

S2-5

S2-4

Clock Mode

Description

 

 

 

 

ON

ON

Internal

3088 provides both the serial

 

 

 

and the DSL clock

 

 

 

 

ON

OFF

External

3088 uses the TX clock from

 

 

 

the serial interface for the DSL

 

 

 

clock.

 

 

 

 

OFF

OFF

Receive-

3088 uses the RX clock from

 

 

Recover

the DSL interface for the

 

 

 

serial clock.

 

 

 

 

OFF

OFF

 

Reserved

 

 

 

 

16

Page 16
Image 16
Patton electronic 3088 Loops, S2-6, S2-5 - S2-4 Clock Mode, S1-7, S1-6, S1-5, S1-4, S1-3, S1-2, S1-1, Data Rate, kbps