Patton electronic 3088 user manual Parameter, Description, Possible, Default, Values

Models: 3088

1 48
Download 48 pages 47.56 Kb
Page 10
Image 10

Parameter

Description

Possible

Default

Values

Value

 

 

 

 

 

 

Clock

Controls DSL and serial clock

Internal,

Receive

Mode

sources. Internal clock mode

External,

Recover

 

means the 3088 provides its

or Receive

 

 

own clock to both the serial

Recover

 

 

interface and the DSL link.

 

 

 

External clock mode means

 

 

 

the serial interface provides

 

 

 

the clock used for the DSL

 

 

 

link. Receive recover clock

 

 

 

mode means the DSL link

 

 

 

provides the clock to the

 

 

 

serial interface.

 

 

 

 

 

 

Annex

The G.991.2 Annex.

A or B

B

 

 

 

 

Line Probe

A proprietary method to set

Enabled or

Disabled

 

the DSL data rate to the best

Disabled

 

 

rate that both units can sup-

 

 

 

port. Used for rate adaptive

 

 

 

applications. This can only be

 

 

 

used for data rates of 3–36

 

 

 

timeslots.

 

 

 

 

 

 

Loopback

The 3088 provides both a

OFF, LAL,

OFF

 

local loopback (LAL) and a

or RDL

 

 

remote loopback (RDL). This

 

 

 

can be used to troubleshoot

 

 

 

problems.

 

 

 

 

 

 

Pattern

The 3088 provides an inter-

OFF, 511,

OFF

 

nal PRBS pattern generator

or 511E

 

 

and detector that can be

 

 

 

used to run BER tests without

 

 

 

external equipment. The pat-

 

 

 

terns offered are 511 and 511

 

 

 

with errors.

 

 

 

 

 

 

DSL Error

The number of errors allowed

0–255

3

Monitor

in an interval before consider-

 

 

Maximum

ing the interval errored. A

 

 

Intervals

value of 0 disables the error

 

 

 

monitor.

 

 

 

 

 

 

DSL Error

The length, in seconds, of

1–255

1

Monitor

an interval.

 

 

Interval

 

 

 

Time

 

 

 

 

 

 

 

10

Page 10
Image 10
Patton electronic 3088 user manual Parameter, Description, Possible, Default, Values