Patton electronic 3088 user manual Reset Configuration To Factory Defaults

Models: 3088

1 48
Download 48 pages 47.56 Kb
Page 42
Image 42

9.0 RESET CONFIGURATION TO FACTORY DEFAULTS

The configuration can be reset to factory defaults from the software reset mode. This allows a user to recover from a forgotten password. To reset to the configuration, follow these steps:

1.Power down the unit.

2.Set all DIP switches to the OFF position.

3.Connect a PC to the Console port.

4.Open a VT100 terminal emulator (such as HyperTerminal). Config- ure the emulator for 19,200 kbps/1 stop bit/no parity/X-ON X-OFF flow control.

5.Power up the unit. The terminal should display the following mes- sage: “Reset Mode”.

6.Type the ‘*’ key. You will see a ‘: ‘ prompt.

7.Type the command ‘reset’.

8.When the command completes, the unit has been reset to factory configuration.

9.Set the DIP switches to the desired configuration. Power cycle the unit to begin using the new software.