Peavey IPR 4500 Rear Panel, Ac Power Inlet, Note For U.K. Only, Channel Mode Switch High Pass

Models: IPR 3000

1 176
Download 176 pages 3.4 Kb
Page 18
Image 18
Rear Panel

Rear Panel

10

10

9

9AC POWER INLET:

This is the receptacle for an IEC line cord, which provides AC power to the unit. Connect the line cord to this connector to provide power to the unit. Damage to the equipment may result if improper line voltage is used. (See line voltage marking on unit).

Never break off the ground pin on any equipment. It is provided for your safety. If the outlet used does not have a ground pin, a suitable grounding adapter should be used and the third wire should be grounded properly. To prevent the risk of shock or fire hazard, always make sure that the amplifier and all associated equipment is properly grounded.

NOTE: FOR U.K. ONLY

As the colors of the wires in the mains lead of this apparatus may not correspond with the colored markings identifying the terminals in your plug, proceed as follows: (1) The wire which is colored green and yellow must be connected to the terminal which is marked by the letter E, or by the Earth symbol, or colored green or green and yellow. (2) The wire which is colored blue must be connected to the terminal which is marked with the letter N, or the color black. (3) The wire which is colored brown must be connected to the terminal which is marked with the letter L, or the color red.

10CHANNEL MODE SWITCH

HIGH PASS

This position is used to activate the HIGH PASS filter for the corresponding channel. This Linkwitz -Riley filter will limit the frequencies sent to the associated amplifier channel to those frequencies above 100 Hz. In situations where separate subwoofer cabinets are being used, this position would indicate connecting the mid-high frequency speaker cabinet to the channel associated with the HIGH PASS switch.

FULL RANGE

As the name implies, the Full Range position on this switch allows all frequencies to pass to the amplifier. Normally used when connecting a full range speaker enclosure to the amplifier's output.

SUBWOOFER

This position is used to activate the LOW PASS filter for the corresponding channel. This Linkwitz-Riley filter will limit the frequencies sent to the associated amplifier channel to those frequencies below 100 Hz. In situations where separate subwoofer cabinets are being used, this position would indicate connecting the subwoofer speaker cabinet to the channel associated with the Subwoofer switch.

18

Page 18
Image 18
Peavey IPR 4500 manual Rear Panel, Ac Power Inlet, Note For U.K. Only, Channel Mode Switch High Pass, Full Range, Subwoofer