Pelco C636M-F manual Click Open. The following dialog box appears

Models: C636M-F

1 86
Download 86 pages 12.48 Kb
Page 72
Image 72
Manual background

4.Click Open. The following dialog box appears.

Figure 88. Device 1 Data Translator Driver Dialog Box

5.Click Configure. The following dialog box appears.

Figure 89. CM9760 Relay Configuration Dialog Box

6.Set the baud rate to 4800 and the parity to Even. The data translator should have these same settings.

7.Enter 1 in the COM Port field. This is the port on the recorder that connects to the data translator. The system defaults to COM 2.

8.Set the Time Synch Update. This is the interval that the recorder updates the CM9760 clock. The default is 21,600 seconds (6 hours).

9.Click OK.

10.Click Test.

11.Close the I/O Handler Configuration application.

72

C636M-F (3/09)

Page 72
Image 72
Pelco C636M-F manual Click Open. The following dialog box appears