DATA TRANSLATOR CONFIGURATION
Integrating a data translator serves two functions:
•Synchronize time between the DX9100 system and the matrix switcher.
•Send ASCII command strings to the matrix switcher (CM6800/CM9740/CM9760) for alarm conditions, such as sending alarms based on motion detection.
NOTE: This programming is required only on the recorder that is physically connected to the
Follow these steps to configure a data translator unit.
1.Go to Start > Programs > DX9000 Server > IO Handler Configuration. The following dialog box appears.
NOTE: You can also open the I/O Handler from the DX9000 Server Configuration Utility.
Figure 86. Data Translator I/O Handler Configuration Dialog Box
2.Click Select Driver on Device 2 to define the external device driver that is connected to the server. The following dialog box appears.
Figure 87. CM9760 Data Translator Driver Dialog Box
3.Select CM9760DT.dll.
| 71 |