Philips SCD 469 manual Clearing telephone numbers from the memory, Changing the sensitivity time

Models: SCD 469

1 188
Download 188 pages 46.31 Kb
Page 13
Image 13
Clearing telephone numbers from the memory

English 13

Clearing telephone numbers from the memory

When the memory is full or when a telephone number stored in the memory is no longer correct or required, follow the procedure below to clear telephone numbers from the memory of the baby unit.

1Press the M (memory) button. (Fig. 12)

,M1 blinks on the display and the corresponding telephone number appears.

2Press the M (memory) button until the telephone number you want to clear appears on the display.

3Press the 0 button.

4Briefly press the C (clear) button on the keypad. (Fig. 11)

,The memory icon (M1-M5) starts to blink and 0 disappears from the display.The telephone number has been cleared and the memory location is free again.

5Repeat the above steps to clear other telephone numbers.

Note:To clear all telephone numbers at once, press the RESET button. All other settings are cleared as well. See ‘Resetting the baby unit’.

Changing the sensitivity time

1Press the PRG button to enter the program mode.

2Press the Ö button.

,Ö and 10 start to blink on the display.

3Use the numeric keypad to enter a new sensitivity time between 10 and 360 seconds.

4Press the OK button to confirm the setting.

Resetting the baby unit

Note:If you press the RESET button, all settings are cleared from the memory of the baby unit.

1Press the RESET button for about 5 seconds.

,The baby unit gives a short beep to confirm.

,When you hear a double beep, the baby unit has been reset to its default settings.

,After a few seconds, M1 starts to blink on the display.The baby unit is now in Quick Install mode.

2Enter new settings, if desired.

Cleaning and maintenance

1Clean the baby monitor with a damp cloth.

Do not immerse the parent unit and the baby unit in water and do not clean them under the tap.

Replacement

Parent unit

If the battery pack of the parent unit needs to be recharged more often than usual, replace it with a new one.You can obtain a new battery pack at the shop where you bought the baby monitor.

Note:Always replace the battery pack with one of the same type: SBC EB4880, 4.8V, 800 mAh.

1Turn the locking knob in the bottom a quarter turn (1) and slide the battery compartment lid downwards to remove it (2). (Fig. 22)