Sensaphone® Model 1108 User’s Manual
For example, if a magnetic reed switch (a normally- closed sensor used to detect unauthorized entry) has been wired to the Model 1108, make sure that the door or window to be monitored is shut before con- figuring the input. If a
5.1.1Programming Input Configuration
1.Press STANDBY to place the Model 1108 in Standby mode.
2.Wire sensors to the inputs to the back of the Model 1108 (see Chapter 2, Section 2.10).
3.Press RUN. The red light glows when the Model 1108 returns to Run mode.
4.Press SET.
5.Press CONFIGURE.
6.The Model 1108 audibly recites the configuration for each of the eight inputs:
•If the input is normally open, the Model 1108 recites the number of the input and says “OK.”
•If the input is normally closed, the Model 1108 recites the number of the input, followed by a “beep” and “OK.”
•If the input is configured as temperature, the Model 1108 recites the number of the input, followed by “Temperature.”
5.1.2Verifying Input Configuration
Input configuration can be verified when interrogating the Model 1108 for a complete Status Report. Refer to Chapter 6 for a more detailed description of the Status Report.
68