Communications / Dial-out:

Problem

Cause

Solution

1. The Model 1108 fails to dial out.

a)

The telephone number may be incorrectly

Recheck programming steps.

 

 

programmed.

Refer to Chapter 4, Section 4.2.1.

 

b)

Tone or pulse (the current dialing

Switch from the current setting: from tone to

 

 

method) is not compatible with the

pulse, or from pulse to tone.

 

 

telephone line on which the Model 1108

Refer to Chapter 4, Section 4.3.

 

 

is installed.

 

 

c)

Recognition Time is too long. An alert

Reprogram Recognition Time. Set the

 

 

condition does not remain in effect long

Recognition Time to the minimum duration

 

 

enough to become a valid alarm.

required to create a valid alarm. If possible,

 

 

 

test the new setting by deliberately creating an

 

 

 

alert condition.

 

 

 

Refer to Chapter 5, Section 5.3.

 

d)

Max Calls is set to zero.

Reprogram Max Calls. It is a good idea to set

 

 

 

your Max Calls to at least equal the number of

 

 

 

dial-out telephone numbers programmed.

 

 

 

Refer to Chapter 4, Section 4.12.1.

117

Appendix B: Troubleshooting

Page 117
Image 117
Phonetics 1108 user manual Communications / Dial-out Problem Cause Solution