Test the heart rate feature on the M9.33 and M9.35.
a.Turn the unit ON. The Precor banner appears in the display.
b.Face the display and straddle the running belt.
c.Place both hands on the
d.When the test is completed, turn the treadmill OFF and continue with step 13.
Note: If the blinking Hr does not appear, turn the unit OFF. Recheck the cable connections beneath the handrail clamp and ask someone else to test the heart rate feature.
Replace the lower handrail clamp using the fasteners removed in step 8. Finger tighten.
Secure the handrails to the lower handrail clamp using two socket head screws (E) and two washers (F).
Tighten all mounting screws.
a.Start at the front of the unit and alternately tighten the four front panel screws.
b.Wrench tighten the four side upright screws.
c.Wrench tighten the two handrail side screws.
d.Wrench tighten the six handrail clamp screws.
e.Wrench tighten the four side rail screws at the base of the handrails.
Lower the treadmill incline to zero using the INCLINE ▼ key. Turn the treadmill OFF.
Make sure the power cord is plugged into an appropriate outlet.
Important: The treadmill requires a dedicated, grounded circuit. A
Check the alignment and adjust the running belt. For instructions, refer to Checking the Alignment and Adjusting the Running Belt.
M9.3x | 6 |