Chapter 6: Settings

Discrete 2 of 5

6.20.1.14 Discrete 2 of 5

Enabled

Set this parameter to on to enable “Discrete 2 of 5”.

Set Length L1 And Set Length L2

Lengths for “Discrete 2 of 5” can be set for Any length, Length within a range, One discrete length or Two discrete lengths. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).

Double-tapping on this parameter displays a dialog box labelled Set Code Lengths where you can define the code length that will be recognized by your scanner.

Choosing One discrete length allows you to decode only those codes containing a selected length. Choosing Two discrete lengths allows you to decode only those codes containing two selected lengths. Length within a range allows you to decode a code type within a specified range from 1 to 12.

Field Size/Char

Refer to page 117 for details.

6.20.1.152D PDF-417(not supported)

Enable

Setting this parameter to on enables PDF-417 two dimensional (2D) coding.

Field Size/Char

Refer to page 117 for details.

6.20.1.16 2D Micro PDF-417 (not supported)

Enable

Setting this parameter to on enables “2D Micro PDF-417” bar code scanning. Micro PDF-417 is a multi-row symbology that is useful for applications requiring greater area efficiency but lower data capacity than PDF-417.

Code 128 Emulation

When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols.