RIC-E1Installation and Operation Manual

 

 

Chapter 1 Introduction

 

 

 

Diagnostics

 

Complies with ITU V.54 (loop 3)

 

Local Loopback

Activated by:

 

 

Internal jumper (RIC-E1)

 

 

Front panel pushbutton (RIC-E1/R)

 

 

DTE circuit 141 for V.35, RS-530 and V.36

Power

AC Source

100 to 240 VAC (± 10%), 50 or 60 Hz

 

DC Source

-48 VDC (-36 to -72 VDC)

 

 

24 VDC (18 to 36 VDC)

 

Power Consumption

Standalone: 3W, max

 

 

RIC-E1/R: 5.2W

 

Fuses

Standalone RIC-E1: 250 mA 250V slowblow

 

 

RIC-E1/R: 500 mA 250V slowblow

Physical

RIC-E1

 

 

 

 

Height

39.5 mm / 1.5 in

 

Width

190 mm / 7.4 in

 

Depth

160 mm / 6.2 in

 

Weight

 

0.6 kg

/ 1.3 lb

Environment

RIC-E1/R

Fits one slot in the ASM-MN-214 card cage

 

0–50 C (32–122 F)

 

Temperature

 

°

°

 

Humidity

Up to 90%, non-condensing

Technical Specifications

1-5

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 19
Image 19
RAD Data comm RIC-E1 operation manual Diagnostics, Power, Physical, Environment