RIC-E1Installation and Operation Manual

Appendix D IR-IP Interface Module

 

 

 

 

 

 

 

 

 

D.13 Erasing User’s Configuration

The user-defined configuration parameters are stored in the IP router card flash memory. After the user-defined configuration parameters are erased, the IP router card automatically loads the factory-default parameters.

You may want to erase the current configuration parameters:

1.Before IR-IP is prepared for operation in a new application.

2.When you cannot configure IR-IP because its current LAN-interface IP address and/or the Telnet password, are not known.

To erase the user’s configuration:

1.Turn RIC-E1 off.

2.Set all the four sections of the IR-IP DIP switch (Figure D-4) to ON.

3.Turn RIC-E1 on and monitor the ERR indicator: it must turn on and start blinking.

4.While the ERR indicator is blinking (within 15 seconds), set sections 1 and 2 of the DIP switch to OFF.

When the ERR indicator stops blinking and lights steadily, the IP router configuration becomes erased.

Note

 

If you do not set sections 1 and 2 to OFF within 15 seconds of power-up, the IP

 

 

router card ignores the setting of all the four sections to ON and starts normal

 

operation. In this case, it is recommended to turn the RIC-E1 off and then back on.

 

To abort the whole operation, turn RIC-E1 off, return all the four-switch section to

 

the desired positions, and then turn the RIC-E1 on again.

 

5. Turn RIC-E1 off, and the return all the four sections of the DIP switch to the

 

desired positions.

D.14 Erasing IR-IP Software

You may erase the IR-IP application software, without erasing the user-defined parameters.

After the application software is erased, IR-IP starts its TFTP server application, and waits for the downloading of software by a TFTP client connected to its LAN interface. The procedure to be used to download the application software in this case is also described below.

You may want to erase the application software if the downloading of new software using the Device Control menu (see Figure D-19) fails, and the IP router card does not function properly.

Erasing IR-IP Software

D-31

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 87
Image 87
RAD Data comm RIC-E1 Erasing User’s Configuration, Erasing IR-IP Software, To erase the user’s configuration