RIC-E1Installation and Operation Manual

Appendix B IR-ETH Interface Module

 

 

Figure B-5. IR-ETH DIP Switch and LED Locations

Setting the DIP Switch

Table B-2describes functions and default settings of the DIP switch SW-1 sections.

The DIP switch is located on the reverse side of the IR-ETH module. To change the switch settings, you must undo three screws on the board and detach the module from the main unit.

Table B-2. DIP Switch Settings

Section

Name

Description

Default Setting

 

 

 

 

1

SQ/FD

ON – Full-duplex operation

 

 

 

OFF – Half-duplex operation

OFF

 

 

 

 

2

CMP

ON – Strips padding bits inserted in 64-byte frame

 

 

 

OFF – Transmits frames over WAN as is

OFF

 

 

 

 

3

FIL

ON – Passes only frames destined for another LAN

 

 

 

OFF – Disables LAN filter; passes all frames transparently

OFF

 

 

 

 

4

Permanently OFF

 

 

 

 

LED Indicators

Table B-3and Table B-4list the IR-ETH LED indicators and describe their functions. Table B-3.IR-ETH LED Indicators, Standalone RIC-E1

LED Name

Description

Location

Color

 

 

 

 

LINK

ON – Good link integrity

Rear panel

Green

Note: The LINK indicator is not available for the IR-ETH module with BNC connector.

 

COLL

ON – Collision occurred on the attached Ethernet segment

Rear panel

Yellow

 

 

 

 

 

 

 

 

 

 

RX

ON – Data is received from the Ethernet attached segment

Rear panel

Yellow

 

 

 

 

 

 

 

 

 

 

TX

ON – Data is transmitted from RIC-E1 to the attached Ethernet

Rear panel

Yellow

 

 

 

 

segment

 

 

 

 

 

 

 

 

 

 

 

 

ERR D4

ON – Bridge buffer overrun

IR-ETH board

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation and Operation

B-5