Appendix D IR-IP Interface Module RIC-E1 Installation and Operation Manual
D-20 Advanced Setup Menu

CIR

Used to specify the maximum amount of data, in bits, which the Frame Relay
network guarantees to transfer during the measurement interval (the measurement
interval is usually one second).
The value of this parameter is obtained from your Frame Relay service provider.

EIR

Used to specify the maximum amount of data, in bits, that the Frame Relay
network will attempt to deliver during the measurement interval. The value of this
parameter is obtained from the Frame Relay service provider.
A typical Frame Relay Protocol Parameters menu is shown in Figure D-15.
IR_IP <IR-IP> S/W Ver. 1.21 31/IR (date)
Quick Setup
Management Access
Advanced Setup
.....................................................................
Device identification
Interface Parameters
Protocol Parameters
=====================================================================
1. Self Learn :[ Enabled ]
2. Maintenance Protocol :[ ANSI T1.617 ANNEX D ]
3. DLCI (0-None) :0..
4. CIR :0.......
5. EIR :64000...
Press one of the numbers to select or ESC:
Figure D-15. Frame Relay Protocol Parameters Menu
WAN Protocol Parameters – PPP Protocol
The PPP Protocol Parameters menu is used to configure the parameters PPP WAN
for protocol (the WAN protocol is selected by means of the (the WAN protocol is
selected by means of the Quick Setup Menu) in Figure D-8.
To access the Protocol Parameters menu:
From the Advanced Setup menu, type 3.

Header and Control Field Compression

Used to control the use of header and control field compression type according to
RFC 1661. It is strongly recommended that this compression be used for
troubleshooting only.

Protocol Field Compression

Used to control the use of protocol field compression type according to RFC 1661.
It is strongly recommended that this compression be used for troubleshooting only.

Authentication Protocol

Used to select the authentication protocol used by an IP router configured as host
to validate incoming connections.