RIC-E1Installation and Operation Manual

Appendix C IR-ETH/V Interface Module

 

 

Setting the DIP Switches

Configure the IR-ETH/V module by setting the DIP switches SW1 and SW2 in accordance with Figure C-4,Table C-2and Table C-3.

Note Reset RIC-E1 for changes in the flow control and LAN filtering switches to take effect.

Table C-2. DIP SW1 Switch Settings

Section

Name

Description

Possible Settings

Factory Setting

 

 

 

 

 

1

MDI

Enables or disables

ON – Automatic MDI/MDIX crossover

 

 

 

automatic MDI/MDIX

is disabled

 

 

 

crossover

OFF – Automatic MDI/MDIX

OFF

 

 

 

crossover is enabled

 

 

 

 

 

 

 

 

 

2, 3

NC

 

 

 

 

 

4

FLC

Enables or disables flow

ON – Flow control/Backpressure is

ON

 

 

control (full duplex) /

enabled

 

 

 

backpressure (half

OFF – Flow control/Backpressure is

 

 

 

duplex)

disabled

 

 

Note: Flow Control (full duplex) is active

 

 

 

 

only if autonegotiation is enabled

 

 

 

 

 

 

 

5

FIL

Enable or disable LAN

ON – LAN filtering is disabled

 

 

 

filtering

OFF – LAN filtering is enabled

OFF

 

 

 

 

 

6

FP

Enable or disable fault

ON – Fault propagation is disabled

ON

 

 

propagation

OFF – Fault propagation is enabled

 

Note: When fault propagation is enabled, the LAN interface shuts down if a failure is detected on the E1 line. When fault propagation is disabled, the link integrity is not influenced by the E1 behavior.

7, 8 NC

 

Note

Sections 2, 3, 7, and 8 of the SW1 DIP switch are factory-set and must not be

 

moved by the user.

 

 

 

 

 

 

 

 

Table C-3. DIP Switch SW2 Settings

 

 

 

 

 

 

Section

Name

Description

Possible Settings

Factory Setting

 

 

 

 

 

1

100

Selects the LAN speed

ON – LAN speed is set to 10 Mbps

 

 

 

 

OFF – LAN speed is set to 100 Mbps

OFF

 

 

 

 

 

2

AN

Controls the LAN

ON – LAN autonegotiation is disabled

 

 

 

autonegotiation

OFF – LAN autonegotiation is enabled

OFF

 

 

 

 

 

3

FDX

Selects the LAN duplex

ON – LAN half duplex mode

 

 

 

mode

OFF – LAN full duplex mode

OFF

 

 

 

 

 

4, 5, 6

NC

 

 

 

 

 

 

 

Notes

 

 

Sections 4, 5, and 6 of the SW2 DIP switch are factory-set and must not be

 

 

moved by the user.

 

 

When autonegotiation is enabled, LAN speed and LAN duplex mode are configured automatically (sections 1 and 3 are disabled).

Installation and Operation

C-5