Chapter 2 Installation and Setup

RIC-E1Installation and Operation Manual

 

 

 

 

 

 

 

 

 

2.3 Configuring RIC-E1

This section provides information on the functions and locations of RIC-E1 internal jumpers. Use this information to select the correct setting for your particular application.

To install RIC-E1:

1.Determine the required configuration, according to your application, and set the internal jumpers accordingly. For more information, refer to Setting the Jumpers.

2.Connect the DTE and G.703 link interfaces, as explained in Connecting the Interfaces.

3.Connect the power to the unit. For more information, refer to Connecting the Power.

Setting the Jumpers

This section explains how to set the internal jumpers according to your requirements. Figure 2-1shows the RIC-E1 jumper locations.

Avoid adjusting, maintaining or repairing RIC-E1 while it is connected to the power source.

Adjusting, maintaining and repairing RIC-E1, while connected to power supply Warning should only be done by a skilled technician aware of the hazards involved.

Capacitors inside the instrument may still be charged even after the instrument has been disconnected from its source of supply.

To set the jumpers:

1.Disconnect the power cable from the mains outlet.

2.Slide the blue side panel forward to detach it from the case.

3.Unscrew the two screws located on the bottom panel at the rear end of the unit.

4.Separate the two halves of the RIC-E1 case by lifting the top cover at the end of the unit and sliding it forward.

5.Adjust the RIC-E1 internal jumpers, as described in Table 2-1.Figure 2-1shows the jumper locations.

6.Reinstall the cover and tighten the screws.

2-2

Configuring RIC-E1

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 22
Image 22