RIC-E1Installation and Operation ManualChapter 5 RIC-E1/R Card

Table 5-1. RIC-E1/R Jumper Settings (Cont.)

Jumper

Description

Values

Default Setting

 

 

 

 

PNL SW, JP5

Enables activation of the

EN – The LLB can be activated via

EN

 

local analog loopback via

the front panel

 

 

the front panel pushbutton

DIS – The LLB cannot be

 

 

 

 

 

 

activated via the front

 

 

 

panel

 

Note: The JP5 jumper is not available for RIC-E1/R cards with IR-ETH and IR-ETH/Vinterface modules.

For RIC-E1/R with IR-IP interface module, the JP5 jumper serves for enabling or disabling the IP LEARN pushbutton.

TX&RX CODE, JP6

Selects the data receive

HDB3

HDB3

 

and transmit coding

AMI

 

 

 

 

 

 

 

 

TIMING SEL, J2

Selects the clock reference

RCV – Receive clock

RCV

 

 

EXT – External clock

 

 

 

INT – Internal clock

 

Note: Units with the IR-ETH, IR-ETH/Vand IR-IP interface modules support only receive and internal clocks.

CHASS GND, J3 Controls the connection between the RIC-E1/R signal ground and the frame (chassis) ground

CON – Signal ground is

CON

connected to the frame

 

ground

 

DISCON – Signal ground is

 

disconnected from the

 

frame ground

 

Installing RIC-E1/R into the ASM-MN-214 Card Cage

To install the RIC-E1/R card in the ASM-MN-214 card cage:

1.Install the ASM-MN-214 card cage in the 19-inch rack.

2.Insert the RIC-E1/R card into one of the ASM-MN-214 slots.

3.Push the card into the cage until it is fully inserted into the edge connector inside the rack.

4.Tighten the screws on front panel of the modem card.

Connecting the Interfaces

RIC-E1/R uses the ASM-MN-214 rear panel terminal block ports for the line connections. The 25-pin D-type female connector serves as a DTE port.

1.Remove the protection cover from the terminal block connectors.

2.Connect the terminal block to the ASM-MN-214 terminal block connector.

3.Connect the line to the terminal block as follows: connect transmit pair to the terminals marked XMT, the receive pair to the terminals marked RCV, and the fifth screw to ground (optional).

Installing the RIC-E1/R Card

5-7

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Page 39
Image 39