5 Commissioning the Tiller Pilot

54

ST1000 Plus & ST2000 Plus Tiller Pilots - Owner’s Handbook

Checking the wind instrument interface

If you have connected the tiller pilot to a wind instrument, check the data link as follows:

1.Press standby and auto together.

2.The tiller pilot should display a ‘W’ followed by the locked heading.

D3270-2

If the display continues to show a flashing ‘C’ and the current heading, the tiller pilot is not receiving any wind data. The most likely reason is a cabling error – either open circuit, short circuit or wires reversed.

Checking the SeaTalk interface

If you have linked the tiller pilot to other instruments or control units via SeaTalk, check the link as follows:

1.Press standby.

D3271-2

Page 58
Image 58
Raymarine ST1000 Plus & ST2000 Plus manual Checking the wind instrument interface, Checking the SeaTalk interface