READER POINT SETTING [EDIT]

JThere is no Add and Delete function for Reader Point Setting. Reader points are configured automatically at the time of device setting automatically, provided with default values appropriately for the device operations. Editing the reader point setting is provided for changes and further refining of the settings.

1.From the upper menu, select [System Management] > [Reader Point Setting].

2.Select an item to change using [Quick Find] in the tool bar.

3.Available reader points are listed in the [Select Reader Point] list on the right pane of the screen.

JReader points displayed may differ from device’s type that is registered in the Device Setting.

4.You can set output signal’s duration for each item listed in the [Select Reader Point]. For example, you can specify the signal duration for which output for how many seconds long whenever the Reader 1 OK event occurs on the reader connected to the controller. In general, Output 1 is set to 03 seconds of activation when the Reader 1 OK event occurs.

JOutput operation configuration each reader points may differ from devices. For further details, refer to the controller’s product documentation.

5.Select a reader point to be edited from the [Select Reader Point] list, and configure the output time settings.

6.Click Save <> in the tool bar.

7.Click Transmit button < > in the toolbar to send the configuration to the device.

JTo confirm the data transmission and its result, run the [Monitoring] > [Integrated Monitoring] from the toolbar before clicking the transmit button.

The data transmission result of each item will be displayed in the [Auditing Log] window of the integrated monitoring screen.

MANAGEMENT SYSTEM

English _89