system management
9.Select a
10.Select whether to use the Graphic Map in [Use Graphic Map]. This field is an optional item, set this if required. Use this when you assign icons for inputs on a graphic map.
11.Select an [Icon]. This field is an optional item, set this if required. Sets the icon for the input.
12.Move to the [Output Time Setting] tab.
13.You can set output signal’s duration for each input point. For example, pressing the exit button requires signaling the door contact of the corresponding door to open it. In general, Output 1 is set to 03 seconds of activation when the exit button is pressed.
14.Select an input point to be edited from the [Select Input] list, and configure the output time settings.
15.Click Save <> in the tool bar.
16.Click Transmit button < > in the toolbar to send the configuration to the device.
J To confirm the data transmission and its result, run the [Monitoring] > [Integrated Monitoring] from the toolbar before clicking the transmit button. The data transmission result of each item will be displayed in the [Auditing Log] window of the integrated monitoring screen.
INPUT POINT SETTING [SEARCH]
1.In the left [Search] tab of the main screen, select [System Management] > [Search Input Point].