system management
2.Select an item to change using [Quick Find] in the tool bar.
3.Available output points are listed in the [Select Output] list on the right pane of the screen.
J Output points displayed may differ from device’s type that is registered in the Device Setting.
4.Select an output point to be edited from the [Select Output] list.
5.Move to the [Basic Setting] tab.
6.Enter the [Output Name].
7.Select an [Output Type]. Select [Door Lock] when the output is connected to a door lock, [Door Alarm] for door alarm devices, or [General] for other devices.
8.Select the [Time Schedule]. This field is an optional item, set this if required. Set the time schedule for each output, if its function is linked to a time schedule. You can set the output to operate only for the time specified in the time schedule.
9.Select a
10.Select whether to use the Graphic Map in [Use Graphic Map]. This field is an optional item, set this if required. Use this when you assign icons for inputs on a graphic map.
11.Select an [Icon]. This field is an optional item, set this if required. Sets the icon for the input.
12.Click Save <> in the tool bar.
13.Click Transmit button < > in the toolbar to send the configuration to the device.
J To confirm the data transmission and its result, run the [Monitoring] > [Integrated Monitoring] from the toolbar before clicking the transmit button. The data transmission result of each item will be displayed in the [Auditing Log] window of the integrated monitoring screen.