Clearing and Adjusting the Printer
2
36
D Press {U} or {T} to display "Fus- er Adjust", and then press {Enter}.
Color Regist.:
Fuser Adjust
Important
❒When the toner cartridge is al- most empty or "Auto Adjust” is not finished, the following mes- sage appears on the panel dis- play and Fuser Adjust is not available.
Cannot Adjust
See User’s Guide
Confirm that the toner cartridge is installed. The toner cartridge must be installed. See P.3 “Replacing the Toner Cartridge”.
If the toner cartridge is installed, perform "Auto Adjust". See P.34 “Auto Adjust”.
E Press {U} or {T} to display "At Unit Replace", and then press {En- ter}.
Fuser Adjust:
At Unit Replace
F Confirm that "Print" is displayed on the menu for printing the test sheet, and then press {Enter}.
Test Sheet:
The following message appears on the panel display.
Set Sheet in
Bypass, then #
G Confirm that the A3 paper which comes with the Fusing Unit is in the Bypass Tray, and then press {Enter}.
The printer prints 8 Test Sheet (A -
H). For details about Test Sheet, see P.40 “Test Sheet Samples”
H Check the test sheets and select the correction value for A through H.
•Select "1", if black and magenta square overlap sharply and you can see white slits as the sample.
•Select "0", if black and magenta square do not overlap sharply and you can not see white slits clearly.
A B C D E F G H 0 0 0 0 0 0 0 0
Press {U} or {T} to select "0" or "1" as the values for A - H. Press {En- ter} to move to the next letter. After setting the value for "H", press {En- ter} and the printer returns to "At Unit Replace".
Note
❒If you select "0" for each alpha- bets or an invalid value is select- ed, an error message is displayed and the printer re- turns to "At Unit Replace". In this case, try again from step E.
Invalid Value
Cannot Adjust
I Press {On Line}.
"Ready " appears on the panel dis- play.
Ready