Replacing Consumables and Maintenance Kit
U Check the test sheets and select the correction value for A through H.
• Select "1", if black and magenta
1 square overlap sharply and you can see white slits as the sample.
•Select "0", if black and magenta square do not overlap sharply and you can not see white slits clearly.
A B C D E F G H 0 0 0 0 0 0 0 0
Reference
⇒P.3 “Replacing the Toner Car- tridge”
⇒P.34 “Auto Adjust”
⇒P.35 “When replacing the fus- ing unit”for "Fuser Adjust"
Press {U} or {T} to select "0" or "1" as the values for A - H. Press {En- ter} to move to the next letter. After setting the value for "H", press {En- ter}, and the printer returns to the ready condition.
Ready
Important
❒If you select "0" for each alpha- bets or an invalid value is select- ed, an error messag e is displayed. In this case, press {Enter} to return to the ready condition, and perform the "Fuser Adjust" manually. See P.35 “When replacing the fusing unit”.
Invalid Value
Press #
❒When "Toner is Almost Empty" appears on the panel display, replace the toner cartridge and perform the "Auto Adjust", and then perform "Fuser Adjust" manually.
22