4 Installation

 

 

MNA1MLSDM00EN, V2.01, 07.2009

4.3Electrical installation

4.3.1Connecting the sensors

The sensors are equipped with an M8 x 1 connector.

 

4

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

+

 

 

 

1

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 (+)

3 (-)

 

 

4

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PNP

 

 

 

 

 

 

 

 

NPN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M8

 

 

3

 

 

 

 

 

-

 

 

3

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 4.2 Connection assignment sensors

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin

Description

 

 

 

 

 

Color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

PELV supply voltage (+)

BN (brown)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

PELV supply voltage (-)

BU (blue)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Output

 

 

 

 

 

BK (black)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The cable length is 100 mm. Extension cables are available in various lengths as accessories, see chapter 7 "Accessories and spare parts".

4.3.2Motor connection

See the motor manual for details on connecting the motor.

4.4Checking installation

Verify that you have correctly installed the product after having per- formed the above steps.

￿Verify correct mounting and cabling of the product. In particular, check the mains connection and the 24V connection.

Check the following:

￿Did you connect all protective ground conductors?

￿Do you use correct fueses?

￿Are any live cable ends exposed?

￿Did you properly install and connect all cables and connectors?

￿Did you properly install the sensors?

￿Do the sensors function as required?

￿Is it possible to freely move the carriage with the contact plate for the sensors along the entire travel length?