6 Diagnostics and troubleshooting

PAS4S

 

 

￿

￿

Dismount the coupling housing with the 4 screws.

Pull the elastomer spider off of the clamping hub.

￿Loosen the clamping screw at the clamping hub.

￿Pull the clamping hub off the shaft extension of the linear axis.

￿Mount the elastomer coupling as well as the motor or the gearbox as described on page 51.

6.3.4Replacing the cover strip (and the strip deflection)

@ WARNING

SHARP EDGES

The cover strip has sharp edges. When the cover strip is cut to length, the edges may be particularly sharp.

Wear protective gloves.

Failure to follow these instructions can result in death, serious injury or equipment damage.

When the cover strip is worn, it is recommended that the two strip de- flections be replaced at the same time (deflection unit with brush).

Unless otherwise specified, the standard tightening torques indicated on page 47 apply.

Special tightening torques

 

 

 

 

 

 

Cover strip clamp

 

PAS41

PAS42

PAS43

PAS44

 

 

 

 

 

 

 

 

 

 

Screw ISO 4762 - 8.8

 

M3 x 8

M4 x 8

M5 x 10

M6 x 14

 

 

 

 

 

 

 

 

Wrench size

[mm]

2.5

3

4

5

 

 

 

 

 

 

 

 

Tightening torque

[Nm]

0.6

1.0

1.5

3

 

 

 

 

 

 

 

Table 6.1 Tightening torques cover strip clamp