8 Service, maintenance and disposal

PAS4S

 

 

8.2Maintenance

The maintenance intervals for cleaning and lubrication must be adhered to.

￿Include the maintenance intervals in your maintenance schedule.

8.2.1Cleaning

Due to its design, the product is not susceptible to the ingress of con- taminants and external objects. The guide is located inside the axis body and it is covered.

The product must be inspected and cleaned at regular intervals.

￿Do not use compressed air for cleaning.

￿Remove large particles and dirt from the surface at regular inter- vals.

￿The anodized surface only has a limited resistance to alkaline cleaning agents. Therefore, use only neutral cleaning agents for cleaning.

￿Use only damp, soft and lint-free cleaning cloths to wipe the sur- face.

Cover strip The cover strip is teflon-coated. The friction causes abrasion on the cover strip.

￿Remove abrasion products at regular intervals.

MNA1MLSDM00EN, V2.01, 07.2009

82

Portal axes with ball screw drive

Page 82
Image 82
Schneider Electric PAS4S manual Maintenance, Cleaning