Chapter 12: Parameters

-Parameter addresses on the JW-50FL

Depending on the setting of switch SW3 on the JW-50FL, the addresses of the parameters (in system memory) will vary, as shown below. In this manual, the parameter addresses in the left column of the tables are expressed in their common form.

 

Parameter

Set value for switch SW3

Details of parameter

 

 

 

address(8)

0

1

2

3

4

(Details - See page 12-1)

 

 

 

00

#0300

#1400

#1500

#1600

#1700

IP address

 

 

 

 

 

 

 

 

 

 

 

 

 

01

#0301

#1401

#1501

#1601

#1701

IP address

 

 

 

 

 

 

 

 

 

 

 

 

 

02

#0302

#1402

#1502

#1602

#1702

IP address

 

 

 

 

 

 

 

 

 

 

 

 

 

03

#0303

#1403

#1503

#1603

#1703

IP address, node number

 

 

 

 

 

 

 

 

 

 

 

 

 

04

#0304

#1404

#1504

#1604

#1704

Token monitor time (normally set to 10 ms)

 

 

 

 

 

 

 

 

 

 

 

 

 

05

#0305

#1405

#1505

#1605

#1705

Minimum frame interval (normally set to 0)

 

 

 

 

 

 

 

 

 

 

 

 

 

06

#0306

#1406

#1506

#1606

#1706

 

 

 

 

to

to

to

to

to

to

Reserved area

 

 

 

07

#0307

#1407

#1507

#1607

#1707

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

#0310

#1410

#1510

#1610

#1710

Sending area top address of area 1 for

 

 

 

11

#0311

#1411

#1511

#1611

#1711

local node (Word address)

 

 

 

 

 

 

 

 

 

 

 

 

 

12

#0312

#1412

#1512

#1612

#1712

Sending data length (word) of area 1 for

 

 

address)

13

#0313

#1413

#1513

#1613

#1713

local node area 1

 

 

 

 

 

 

 

 

 

 

 

15

#0315

#1415

#1515

#1615

#1715

local node (Word address)

 

 

 

14

#0314

#1414

#1514

#1614

#1714

Sending area top address of area 2 for the

 

 

memory

 

 

 

 

 

 

 

 

 

16

#0316

#1416

#1516

#1616

#1716

Sending data length (word) of area 2 for

 

 

 

 

 

 

17

#0317

#1417

#1517

#1617

#1717

local node

 

 

 

 

 

 

 

 

 

 

 

 

(System

20

#0320

#1420

#1520

#1620

#1720

Top address (word address) of area 1 on

 

 

21

#0321

#1421

#1521

#1621

#1721

PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

address

22

#0322

#1422

#1522

#1622

#1722

File number of area 1 on PC

 

 

 

 

 

 

 

 

 

 

 

23

#0323

#1423

#1523

#1623

#1723

Reserved area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

#0324

#1424

#1524

#1624

#1724

Top address (word address) of area 2 on

 

 

Parameter

25

#0325

#1425

#1525

#1625

#1725

PC

 

 

 

 

 

 

 

 

 

 

 

26

#0326

#1426

#1526

#1626

#1726

File number of area 2 on PC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

#0327

#1427

#1527

#1627

#1727

Reserved area

 

 

 

 

 

 

 

 

 

 

 

 

 

30

#0330

#1430

#1530

#1630

#1730

Top address of communication control area

 

 

 

 

 

31

#0331

#1431

#1531

#1631

#1731

(word address) on PC

 

12

 

 

 

 

 

 

 

 

 

 

32

#0332

#1432

#1532

#1632

#1732

File number of communication control area

 

 

 

 

 

on PC

 

 

 

 

 

 

 

 

 

 

 

 

 

33

#0333

#1433

#1533

#1633

#1733

Transmission type of communication control

 

 

 

 

 

 

 

 

 

area

 

 

 

33

#0334

#1434

#1534

#1634

#1734

Top address of transmission buffer (word

 

 

 

35

#0335

#1435

#1535

#1635

#1735

address)

 

 

 

 

 

 

 

 

 

 

 

 

 

36

#0336

#1436

#1536

#1636

#1736

File number of transmission buffer

 

 

 

 

 

 

 

 

 

 

 

 

 

37

#0337

#1437

#1537

#1637

#1737

Use selection of transmission buffer

 

 

 

 

 

 

 

 

 

 

 

 

 

40

#0340

#1440

#1540

#1640

#1740

 

 

 

 

to

to

to

to

to

to

Node name (ASCII 10 characters)

 

 

 

51

#0351

#1451

#1551

#1651

#1751

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52

#0352

#1452

#1552

#1652

#1752

 

 

 

 

to

to

to

to

to

to

Reserved area

 

 

 

57

#0357

#1457

#1557

#1657

#1757

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

#0360

#1460

#1560

#1660

#1760

SEND/RECEIVE instruction timeout time

 

 

 

 

 

 

 

 

 

 

 

 

 

61

#0361

#1461

#1561

#1661

#1761

 

 

 

 

to

to

to

to

to

to

Reserved area

 

 

 

76

#0376

#1476

#1576

#1676

#1776

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

#0377

#1477

#1577

#1677

#1777

Start switch

 

 

 

 

 

 

 

 

 

 

 

 