Sharp MZ-3500 service manual On OFF

Models: MZ-3500

1 116
Download 116 pages 54.05 Kb
Page 88
Image 88

Type of error

0)MDF 1/F error

ON OFF

1sec. 4sec.

(2.1 SDO read/write error

(3)SDO bank alternation error

®AD2 bank alternation error

© AD3 bank alternation error

CD ROM sum-check error

© Option RAM read/write error

(Indicated even when the option RAM is not in use)

/s~. Option RAM bank alternation error

NOTES:

1.The MFD I/F will not be tested, if there is no MFD I/F connected or when the diskette was not inserted in the slot of the drive unit No.2.

2.ROM test will not be performed, unless it is a ROM

based machine.

2) Loacing check program

The test program is loaded from the specified track and

sector to start executing the test.

[Procedure]

(1)Set dip switches on of the 4 bit unit located in middle of the front side of the board as illustrated at the right.

No.

1

2

3

4

POSITIONOFF ON ON ON

,2) Set dip switches on of the 2 bit unit located on the front side of the board.

(3)Insert the media into a slot of any diskette drive unit.

(4)Turn the power on

(5)Load the program from the specified track and sector,

to start execution of the test program. [Conditions required for the drive unit and media]

(1)Use the FD-55B for the diskette drive unit.

(2)Program may exist in any sector of any track, provided that it is written in continuous sector within a same track.

(Max. 256 bytes x 16 sectors = 4K bytes)

(3)Data descrived next should have been written on Sector 1 of Track 0.

(4)Program loading address must be 4800H and higher

Page 88
Image 88
Sharp MZ-3500 service manual On OFF