M Z 3500

 

DO~D7

Data Bas

RXD

Receive Data (IN/OUT)

WR

Write (IN)

RD

Read (IN)

C/D

Control/Data (IN/OUT)

CS

Chip Select (IN)

DSR

Data Set Ready (IN)

DTR

Data Terminal Ready (OUT)

RTS

Request to Send (OUT)

CTS

Clear to Send (IN)

TXRDY

. Transmitter Ready (OUT)

TXC

Transmitter Clock (IN)

TXE

. Transmitter Empty (OUT)

RXC

. Receiver Clock (IN)

SYNET/BD

: SYNC Detect/Break Detect (IN/OUT)

2)UPD8253C-5 (Programmable Interval Timer)

The UPD8253-5 is a programmable counter/timer speci- fically designed for the 8-bit microcomputer system. It consists of three sets of 16-bit counters that operate under a maximum counter rate of 4MHz. Timer and six operational modes are programmed to be used for a wide range of microcomputer system timing control.

Features

Z-80 compatible

Three sets of 16-bit counters

DC-4MHz of count rate

Programmable six operational modes and timer duration

Choice of binary counter/BCD counter

N-channel MOS, input/output TTLcompatible

Single +5Vsupply, 24-pin DIP

Intel 8253-5 compatible

Pin configuration (Top View)

.VCC

Block diagram

 

O

Data bus

 

 

 

 

 

Counter

•«

t 1 KO

UO

AA

 

VV

 

 

<l

C . MtO

buffer

 

 

# 0

 

 

v-v

 

 

 

 

'

*-"no

 

 

 

 

 

 

 

 

 

 

 

 

 

 

l

 

_t

 

 

 

 

write

 

 

Interna

 

 

# 1

<

OA1 ^ 1

wl —»<:

Read/

 

 

 

/«--N

 

Counter

<

C 1 K 1

AO

1

logic

 

 

 

\r,V

 

 

 

 

Al

>

 

 

 

£

 

 

 

 

»-()l I 1

 

 

 

 

 

 

 

 

c-

 

^

 

 

 

 

 

t

 

 

 

 

^

 

 

 

 

 

 

 

 

 

 

Control

 

 

 

 

Counter

*-

Cl K2

 

 

/"

'

 

 

 

 

 

word

 

A^S

 

 

«

GA1L2

 

 

register

**w

 

 

S1—K]

# 2

 

 

 

 

 

KHT2

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

t

 

 

 

 

D7-DO

Data Bus (8 bit)

 

 

 

 

CLKN

 

Counter Clock Inputs

 

 

 

GATEN

Counter Gate Inputs

 

 

 

OUTN

 

Counter Outputs

 

 

 

 

RD

 

. Read Counter

 

 

 

 

WR

 

Write Command or Data

 

 

CS

 

Chip Select

 

 

 

 

A1~AO

: Counter Select

 

 

 

 

Vcc

 

. +5 Volts

 

 

 

 

 

 

GND

 

. Ground

 

 

 

 

- 76 -