Sharp MZ-3500 service manual AC controls, Start, Off

Models: MZ-3500

1 116
Download 116 pages 54.05 Kb
Page 65
Image 65

MZ3500

6-3. Block diagram of the interface

6-4. System switch functions

Control signal

Peripheral

ON

SW5 Causes an error when the ER signal is low or open during data output.

SW6 Always high when power is

on to the main unit.

SW7 Causes on error when the PO signal is high during data output.

OFF

ER signal is disabled.

The CD signal is set high while data output, but would not be set high when the echo-back function is selected for the host computer.

Polarity is inverted.

6-5. 8251AC controls

There are two control words for the 8251AC.

(1)Mode instruction: Defining general operational para- meters, such as unit, stop bit, etc.

(2)Command instruction: Defining status words used for actual operation, such assend/receive enable, etc.

1)Definition of generation operational parameters

Baud rate

Character size

Even/odd/off parity assignment

••Stop bit size

"Corresponds to channel command of BASIC.

c START

8251AC internal reset

8251AC mode instruction

- 72 -

Page 65
Image 65
Sharp MZ-3500 service manual AC controls, Start, Off