8 4 System SW1 (DIP SW) (User operative through the cabinet bottom)

M 7 3500

No

1

2

3

4

5

6

7

8

9

10

Signal name

Function

Position

Polarity

 

 

ON

L

SW1

 

OFF

H

 

Printer select

 

 

 

 

 

ON

L

SW2

 

OFF

H

 

 

 

CRT select

ON

L

SW3

OFF

H

 

 

 

Choice of decimal

ON

L

SW4

point output

 

 

 

format

OFF

H

 

 

ON

L

SW5

 

OFF

H

 

 

 

 

ON

L

SW6

RS232C

 

 

assign

 

 

 

 

 

 

 

OFF

H

 

 

ON

L

SW7

 

 

H

 

 

OFF

 

 

ON

L

FD1

Key shift mode

 

 

(SW8)

setup

OFF

H

 

 

 

Choice of CG

ON

L

P/M

 

 

(SW9)

for display

OFF

H

 

 

Description

SW2 SW1

ON ON CE332P

OFF ON MZ1P02

ON OFF IO2824

OFF OFF

High resolution CRT (MZ1D02. MZ1D03)

Medium resolution CRT (MZ1D01, MZ1D06)

A period is output for a decimal point

A comma is outputted for a decimal point

Low state or open ER signal during data output will result in anerror

The signal ER becomes invalid

CD is high as long as power is on to the main unit

CD goes high only during data output However, it would not go high if the echo back function is on the host side

An error is cause when the PO signal is high during data output

Polarity is inverted for the above

Normally in capital letter, but in small letter when shifted

Normally small leter and in capital letter when shifted

3500 CG will be assigned when the 200 raster CRT is in use

2000 CG will be assigned when the 200 raster CRT is in use

#47 pin of MMR

£48 pin of MMR

#51 pin of MMR

#52 pin of MMR

ToCTS, DSR of the 8251

ToCTS of the 8251

#54 pin of MMR (FDD

P/M signal (To A3 CG)

NC

^=— =T

Dip switches (A) and (B) located on the PWB are used for servicing the MFD or for other machine service and there fore the user is not supposed to use these switches In addition, these switch must be used when either the CE 330M or 331M is used as the expansion MFD

DIPSW(A)

No Signal name

 

 

t

 

1

SEC

44 pin of MMR

1

2

3

(SW1A)

OFF

OFF

OFF

 

 

 

 

 

2

FD2

56 pin of MMR

ON

OFF

OFF

(SW2A)

OFF

 

 

 

 

ON

OFF

 

 

 

3

FD3

58 pin of MMR

ON

ON

OFF

(SW3A)

 

 

 

 

 

OFF

OFF

ON

 

 

 

4

SRQ

Bus request

ON

OFF

ON

(SW4A)

to sub-CPU

 

 

 

 

OFF

ON

ON

 

 

 

 

 

 

ON

ON

ON

WhenSH in use

When DH in use

Use of the CE330M as an expansion unit Use of the CE331M as an expansion unit Check mode *1

Check mode *2

DIPSW (B)

 

 

*1

Test program is loaded and executed

 

 

 

 

No

Signal name

 

 

*2

Provided for the test of the MFD interface The

1

SRES

SUB CPU

 

 

read/write test is carried out for the expansion unit

 

 

 

(SW1B)

reset signal

 

 

 

 

\

 

 

 

 

SUB CPU BUS

Used for an individual test of the CPU PWB When these

2

SW2B

 

 

 

 

select signal

 

three switches are turned off altogether, it makes the

 

 

 

sub CPU operated independently To be used in th ON condition under a normal situation

Page 78