Lamp/Maintenance Indicators
Maintenance Indicators
TEMP LAMP2 LAMP1 POWER
2 | 1 |
TEMPERATURE | LAMP 2 | LAMP 1 | POWER |
WARNING | REPLACEMENT | REPLACEMENT | indicator |
indicator | indicator | indicator |
|
•The warning lights on the projector indicate problems inside the projector.
•There are three warning lights: a TEMPERATURE WARNING indicator that warns you when the projector is too hot, and two LAMP REPLACEMENT indicators that warn you when to change a lamp.
•If a problem occurs, either the TEMPERATURE WARNING indicator or the LAMP REPLACEMENT indicators will light up red. After turning off the power, follow the procedures given below.
&Troubleshooting
Maintenance
Maintenance Indicator | Condition | Problem | Possible Solution |
TEMPERATURE | The internal | • Blocked air intake. | • Relocate the projector to an area with |
WARNING indicator | temperature is |
| proper ventilation. |
| abnormally high. | • Clogged air filter. | • Replace the filter. |
|
|
| (See page 73.) |
|
| • Cooling fan breakdown. | • Take the projector to your nearest |
|
| • Internal circuit failure. | Authorized Sharp Industrial LCD Products |
|
|
| Dealer or Service Center for repair. |
LAMP REPLACE- | The lamp does not | • | • Carefully replace the lamp. (See pages 71 |
MENT indicator | light up. | • Lamp circuit failure. | and 72.) |
|
|
| • Take the projector to your nearest |
| The lamp requires | • Lamp has been used for | Authorized Sharp Industrial LCD Products |
| replacement. | over 900 hours. | Dealer or Service Center for repair. |
POWER indicator | The POWER | • The filter cover is open. | • Securely install the filter cover. |
| indicator flashes in | • The lens cover* is not | • Securely install the lens cover. |
| red when the | ||
| securely installed. |
| |
| projector is on. |
| |
|
|
| |
* The lens cover is as shown below. |
|
| |
| Lens cover |
|
|
•If the TEMPERATURE WARNING indicator lights up, follow the above possible solutions and then wait until the projector has cooled down completely before turning the power back on. (At least 5 minutes.)
•If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicators may be triggered, preventing the power from going on. Should this occur, take the power cord out of the wall outlet and put it back in again.